Permit Info
Short Description:
1 BF FIRE PROT - 5211 AC, 6754 SF, SFR / 2 STORY
Expiration Date:
1/9/2019
Notes:
1 BF FIRE PROT - 5211 AC, 6754 SF, SFR / 2 STORY
9/12/2007 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
2-#4 REBAR IN THE BOTTOM OF ALL BEAMS WITHOUT BEAM STRANDS
12' PIERS WITH 2-#7 REBAR AND #3 TIES 10' OC.
SCREANWALL 12" PIERS WITH 4-#5 REBAR AND #3 TIES 10' OC.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
42. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
2nd FLOOR: 1-BED ROOM, 1-BATH AND A GAME ROOM WITH A COVERED BALCONY.
Parcel Info
City/State/Zip:
FRISCO, TX, 75036
Subdivision:
THE SHORES AT WATERSTONE PH 1
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | HWANG, JAMES | (214)924-5958 | | | FRISCO, TX 75034 |
MAIL TO | HWANG, JAMES | ()- | | | FRISCO, TX 75034 |
APPLICANT | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC X- | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
GEN. CONTR. | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
HERS PROVIDE | THE NELROD COMPANY | (817)922-9000 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
IRRIGATION | HALL'S AUTO SPRINKLER (IRRG) | (972)287-7917 | HALLINC@DMBARQMAIL.COM | 7100 CR 4064 | KEMP, TX 75143 |
PLUM. CONT. | FIVE STAR PLUMBING 05/08 | (972)225-7827 | LTURNER@FIVESTARPLUMBING.COM | 1607 FALCON DRIVE #102 | DESOTO, TX 75115 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)941-8350 | brian@pseglobal.com | 5068 W PLANO PKWY, SUITE 199 | PLANO, TX 75093 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/29/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
1/23/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/25/2018
| | 1/25/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/9/2017
| | 1/9/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/19/2008
| | 2/19/2008 | |
More Info
|
There are currently no reviews on this record.