Permit Info
Short Description:
1 BF FIRE PROT; 35211 AC; 6633 SF., 2 STORY
Expiration Date:
12/2/2018
Notes:
1 BF FIRE PROT; 35211 AC; 6633 SF., 2 STORY
7/30/2007 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
31. SIDING OVER MASONRY AT SECOND STORY NOT ALLOWED.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL
60. BUILDER CAUTION: CONSTRUCTION NOT CONFORMING TO THE ABOVE PERMIT REQUIRMENTS COULD RESULT IN C.O. DELAY OR POSSIBLE DENIAL.
2nd level: game room, 1 bdrm. 1 ba. & unfin. attic
no wood at window surrounds.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034-3386
Subdivision:
THE SHORES AT WATERSTONE PH 1
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | SMITH, SCOTT S & KARLA L | ()- | | | FRISCO, TX 75034 |
MAIL TO | SMITH, SCOTT S & KARLA L | ()- | | | FRISCO, TX 75034 |
APPLICANT | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
CONTRACTOR | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC X-3/08 | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
HERS PROVIDE | THE NELROD COMPANY | (817)922-9000 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGERS HEAT'G & A/C X-05/0 | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | FIVE STAR PLUMBING 05/07 | (972)225-7827 | | 1607 FALCON DRIVE #102 | DESOTO, TX 75115 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)941-8350 | brian@pseglobal.com | 5068 W PLANO PKWY, SUITE 199 | PLANO, TX 75093 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/13/2018
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/6/2018
| | 4/6/2018 | |
More Info
|
BACKFLOW | APPROVED |
12/2/2016
| | 12/2/2016 | |
More Info
|
BACKFLOW | APPROVED |
11/27/2007
| | 11/27/2007 | |
More Info
|
There are currently no reviews on this record.