Permit Info
Short Description:
1 BF FIRE PROT 5870 AC, 6996 SF, SFR / 2 STORY
Expiration Date:
2/25/2019
Notes:
1 BF FIRE PROT 5870 AC, 6996 SF, SFR / 2 STORY
2/14/2007 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
38. RETAINING WALLS 3 FT OR TALLER MUST BE ENGINEERED.
42. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(2/14/2007 13:49 JC)
Piers : 12" dia with (2) # 4's, vertical rebar.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
COUNTRY CLUB RIDGE AT THE TRAILS PH 2
|
| BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
| OWNER | SPRAGLE, THOMAS R | ()- | | | FRISCO, TX 75033 |
| MAIL TO | SPRAGLE, THOMAS R | ()- | | | FRISCO, TX 75033 |
| APPLICANT | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
| CONTRACTOR | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
| ELECT. CTR. | METRO TECH ELECTRIC X-1/07 | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
| GEN. CONTR. | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
| HERS PROVIDE | THE NELROD COMPANY (H.E.R.S. P | (817)922-9000 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
| MECH. CTR. | KRUGERS HEAT'G & A/C X-08/0 | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
| PLUM. CONT. | L & S PLUMBING X- 06/2007 | (972)331-6837 | | 8001 ALPHA DR, STE # 109 | RICHARDSON, TX 75081 |
| STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)941-8350 | brian@pseglobal.com | 5068 W PLANO PKWY, SUITE 199 | PLANO, TX 75093 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
4/13/2018
|
| BACK FLOW FORM REVIEW |
$25.00
|
5/18/2017
|
| Total Fees |
|
Charged: $50.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
4/12/2018
| | 4/12/2018 | |
More Info
|
| BACKFLOW | APPROVED |
5/12/2017
| | 5/12/2017 | |
More Info
|
| BACKFLOW | APPROVED |
2/25/2016
| | 2/25/2016 | |
More Info
|
| BACKFLOW | APPROVED |
8/8/2007
| | 8/8/2007 | |
More Info
|
There are currently no reviews on this record.