Permit Info
Short Description:
1 BF FIRE--7985 AC, 10427 SF, SFR / 2 STORY
Status:
RES LETTER ONE SENT
Expiration Date:
5/2/2018
Notes:
1 BF FIRE--7985 AC, 10427 SF, SFR / 2 STORY
2/16/2006 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
2ND LEVEL: 3 BDRM. 3.5 BATHS, MEDIA & GAME, LIBRARY, & FUTURE GUEST RM.
PROVIDE CRICKET AT MASONRY AT VALLEY FOR WATER RUNOFF
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #1 SPANISH OAKS EST (VLG 4) (CFR)
|
BF TESTER | DANNY R SMITHERMAN | (972)647-8172 | | 1171 RUGGLES DR | GRANDPRAIRIE, TX 75050 |
OWNER | LINDQUIST WILLIAM J & DENISE M | ()- | | | FRISCO, TX 75034-5142 |
MAIL TO | LINDQUIST WILLIAM J & DENISE M | ()- | | | FRISCO, TX 75034-5142 |
APPLICANT | GEORGE C FULLER CONTRACTING X- | (972)562-0231 | | 2405 PROVINE RD | MCKINNEY, TX 75070 |
CONTRACTOR | GEORGE C FULLER CONTRACTING X- | (972)562-0231 | | 2405 PROVINE RD | MCKINNEY, TX 75070 |
ELECT. CTR. | RRC PLUMBING, LLC X-6/2006 | (972)569-9997 | | 601 ISLEWORTH LANE | MCKINNEY, TX 75070 |
GEN. CONTR. | GEORGE C FULLER CONTRACTING X- | (972)562-0231 | | 2405 PROVINE RD | MCKINNEY, TX 75070 |
MECH. CTR. | ARI-TEX ELECTRIC INC X- 10/20 | (972)727-9902 | | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
PLUM. CONT. | ADVENT AIR CONDITIONING, INC | (972)221-4373 | | 500 S. KEALY | LEWISVILLE, TX 75057 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/2/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/2/2017
| | 5/2/2017 | |
More Info
|
BACKFLOW | APPROVED |
7/12/2007
| | 7/12/2007 | |
More Info
|
There are currently no reviews on this record.