Permit Info
Short Description:
1 FIRE BF, 9427 SF, SFR / 2 STORY
Status:
RES LETTER ONE SENT
Expiration Date:
5/8/2018
Notes:
1 FIRE BF, 9427 SF, SFR / 2 STORY
6/20/2006 12:00:00 AM
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
06. BEAMS=8"W X 28"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
42. PROVIDE SOIL MOISTURE TREATMENT DOCUMENTATION PRIOR TO STARTING CONSTRUCTION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
2nd level: 3 bdrm. 4 bath, game rm. & media
------7' min. ceiling heighth under stairs above toilet------------------------------
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD PHASE FOUR VILLAGE NO 17 (CFR)
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | DOSSANI MOHAMED & FARZANA | ()- | | | FRISCO, TX 75034-4080 |
MAIL TO | DOSSANI MOHAMED & FARZANA | ()- | | | FRISCO, TX 75034-4080 |
APPLICANT | PIERCE HOMES | (972)318-1400 | | 1900 FM 407, SUITE #200 | HIGHLAND VILLAGE, TX 75077 |
CONTRACTOR | PIERCE HOMES | (972)318-1400 | | 1900 FM 407, SUITE #200 | HIGHLAND VILLAGE, TX 75077 |
ELECT. CTR. | CIRCLE A ELECTRIC X-1/07 | (817)625-0880 | | 1051 KENNEDY | SAGINAW, TX 76131 |
GEN. CONTR. | PIERCE HOMES | (972)318-1400 | | 1900 FM 407, SUITE #200 | HIGHLAND VILLAGE, TX 75077 |
HERS PROVIDE | ENERGY SENSE X-02-06 | (214)341-0668 | jason.mcalister@mascocs.com | 11111 PLANO ROAD | DALLAS, TX 75238 |
MECH. CTR. | DALLAS PLUMBING CO. (MECHANICA | (214)340-6300 | | P.O. BOX 551648 | DALLAS, TX 75355 |
PLUM. CONT. | DALLAS PLUMBING CO. X-09 | (214)340-6300 | | P.O. BOX 551648 | DALLAS, TX 75355 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/5/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/26/2017
| | 5/26/2017 | |
More Info
|
BACKFLOW | APPROVED |
5/24/2007
| | 5/24/2007 | |
More Info
|
There are currently no reviews on this record.