Permit Info
Short Description:
1 FIRE BF- PROT8504 SF, SFR / 2 STORY
Expiration Date:
1/30/2019
Notes:
1 FIRE BF- PROT8504 SF, SFR / 2 STORY
11/27/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
05. BEAMS=8"W X 26"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
47. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2003 IRC.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(11/27/2006 13:41 JC)
Per CBO, sump pump discharge to storm sewer must have both Eng'n. Dept. and Public Works approval prior to construction. Max. height of stone screen wall is 8'-0". This permit is issued as a single family residential only.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 6A
|
BF TESTER | CHAD ADLER | (972)699-7156 | ADLERWATERWORKS@GMAIL.COM | 11305 KNOXVILLE LN | FRISCO, TX 75035 |
OWNER | BRIDGES, GARY W & KATHY B | ()- | | | FRISCO, TX 75033 |
MAIL TO | BRIDGES, GARY W & KATHY B | ()- | | | FRISCO, TX 75033 |
APPLICANT | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
CONTRACTOR | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC X-1/07 | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
GEN. CONTR. | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
HERS PROVIDE | THE NELROD COMPANY (H.E.R.S. P | (817)922-9000 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGERS HEAT'G & A/C X-08/0 | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | L & S PLUMBING X- 06/2007 | (972)331-6837 | | 8001 ALPHA DR, STE # 109 | RICHARDSON, TX 75081 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
2/2/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
1/19/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/15/2018
| | 1/15/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/30/2017
| | 1/30/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/4/2016
| | 2/4/2016 | |
More Info
|
BACKFLOW | APPROVED |
4/23/2007
| | 4/23/2007 | |
More Info
|
There are currently no reviews on this record.