Permit Info
Short Description:
1 FIRE BF--7209 AC, 9172 SF, SFR / 2 STORY
Expiration Date:
1/14/2019
Notes:
/24/2006 09:46 VI)
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
2ND FLOOR: 3 BEDROOMS, 3 BATHS, LOFT, GAME ROOM, COVERED BALCONY AND LARGE ATTIC.
1 FIRE BF--7209 AC, 9172 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #1 (CFR)
|
| BF TESTER | THOMAS STEHLIK | (214)350-1755 | TJSTEHLIK@HOTMAIL.COM | PO BOX 630886 | IRVING, TX 75063 |
| OWNER | ROMANS KENNETH & ANA | ()- | | | FRISCO, TX 75034-7243 |
| MAIL TO | ROMANS KENNETH & ANA | ()- | | | FRISCO, TX 75034-7243 |
| APPLICANT | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
| CONTRACTOR | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
| ELECT. CTR. | ARI-TEX ELECTRIC INC X- 10/20 | (972)727-9902 | | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
| GEN. CONTR. | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
| MECH. CTR. | CHAPMAN AIR & HEAT X-04/20 | (214)340-4999 | | 10750 SANDHILL | DALLAS, TX 75238 |
| PLUM. CONT. | RELIABLE PLUMBING X- 09/2006 | (972)285-0939 | | 2509 FRANKLIN | MESQUITE, TX 75150 |
| STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
2/1/2018
|
| BACK FLOW FORM REVIEW |
$25.00
|
1/17/2017
|
| Total Fees |
|
Charged: $50.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
1/13/2018
| | 1/13/2018 | |
More Info
|
| BACKFLOW | APPROVED |
1/14/2017
| | 1/14/2017 | |
More Info
|
| BACKFLOW | APPROVED |
1/29/2016
| | 1/29/2016 | |
More Info
|
| BACKFLOW | APPROVED |
4/11/2007
| | 4/11/2007 | |
More Info
|
There are currently no reviews on this record.