Permit Info
Short Description:
1 BF FIRE PROT - 6079 AC, 7465 SF, SFR / 2 STORY
Expiration Date:
11/18/2018
Notes:
1 BF FIRE PROT - 6079 AC, 7465 SF, SFR / 2 STORY
8/5/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
wine grotto--------slab beams 12"x 26" w/2 #5's top & bottom of beams--see dtl.
05. BEAMS=8"W X 26"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
2nd level: 3 bdrm. 2.5 ba. study, tech ctr., game rm., media, playrm.
Parcel Info
City/State/Zip:
FRISCO, TX, 75036
Subdivision:
THE SHORES AT WATERSTONE PH 1
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | COCKRILL, JEREMY C & STEPHANIE | ()- | | | FRISCO, TX 75034 |
MAIL TO | COCKRILL, JEREMY C & STEPHANIE | ()- | | | FRISCO, TX 75034 |
APPLICANT | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
CONTRACTOR | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
ELECT. CTR. | FOX ELECTRIC X-1/07 | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
HERS PROVIDE | THE NELROD COMPANY (H.E.R.S. P | (817)922-9000 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
IRRIGATION | NORTH TEXAS LAWN & LANDSCAPE | (972)240-8082 | | P.O. BOX 2140 | ROCKWALL, TX 75087 |
MECH. CTR. | KRUGERS HEAT'G & A/C X-06/0 | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | FIVE STAR PLUMBING, INC X - | (972)225-7827 | | 1607 FALCON DRIVE #102 | DESOTO, TX 75115 |
|
BACK FLOW FORM REVIEW |
$25.00
|
2/23/2018
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
2/19/2018
| | 2/19/2018 | |
More Info
|
BACKFLOW | APPROVED |
11/18/2016
| | 11/18/2016 | |
More Info
|
BACKFLOW | APPROVED |
3/7/2007
| | 3/7/2007 | |
More Info
|
There are currently no reviews on this record.