Permit Info
Short Description:
1 BF FIRE PROT - 5980 AC, 7407 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
1/25/2017
Notes:
1 BF FIRE PROT - 5980 AC, 7407 SF, SFR / 2 STORY
6/20/2005 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
09. BEAMS=10"W X 26"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
1. Approach must be 100% on inside of setback (build line)
2. 6917 ac & garage
3. 2nd level: 3 bdrm. 3 ba. game & media
(7/11/2005 09:35 MBW) Corrected address to 6446 Bluffview from 6646.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #1 (CFR)
|
| BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
| OWNER | RHODA WILLIAM R | ()- | | | FRISCO, TX 75034-7256 |
| MAIL TO | RHODA WILLIAM R | ()- | | | FRISCO, TX 75034-7256 |
| APPLICANT | LONNIE GRAY CUSTOM | (972)624-1616 | | P.O. BOX 796621 | DALLAS, TX 75379 |
| CONTRACTOR | LONNIE GRAY CUSTOM | (972)624-1616 | | P.O. BOX 796621 | DALLAS, TX 75379 |
| ELECT. CTR. | ML HAMILTON ELECTRIC X-07/05 | (972)725-7512 | | P O BOX 18 | ALLEN, TX 75013 |
| GEN. CONTR. | LONNIE GRAY CUSTOM | (972)624-1616 | | P.O. BOX 796621 | DALLAS, TX 75379 |
| IRRIGATION | SCOGGINS LANDSCAPE | (972)881-0617 | | 3840 THUNDERBIRD LN | PLANO, TX 75023 |
| MECH. CTR. | ABC PLUMBING, INC. X- | (972)423-7477 | | 1909 10TH ST., STE 500 | PLANO, TX 75074 |
| PLUM. CONT. | RIDDELL PLUMBING, INC. x -10/ | (972)682-4860 | | 242 S HWY 352 | SUNNYVALE, TX 75182 |
| STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
| Total Fees |
|
Charged: $0.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
1/25/2016
| | 1/25/2016 | |
More Info
|
| BACKFLOW | APPROVED |
11/7/2006
| | 11/7/2006 | |
More Info
|
There are currently no reviews on this record.