Permit Info
Short Description:
1 BF FIRE PROT - 6454 AC, 8047 SF, SFR / 2 STORY
Expiration Date:
6/26/2018
Notes:
1 BF FIRE PROT - 6454 AC, 8047 SF, SFR / 2 STORY
8/6/2005 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(10/7/2005 15:27 SEL) RCV'D FAX STATING PUCKETT ELECTRIC IS NOT DOING JOB. PLEASE SEE FILE FOR FAX.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034-6917
Subdivision:
STONEBRIAR COUNTRY CLUB ESTATES
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | KENNEDY, SHEA | ()- | | | FRISCO, TX 75034 |
MAIL TO | KENNEDY, SHEA | ()- | | | FRISCO, TX 75034 |
APPLICANT | PARTHENON HOMES X- 06/05 | (972)824-1591 | | 1680 PRINCE WILLIAM LN. | FRISCO, TX 75034 |
CONTRACTOR | PARTHENON HOMES X- 06/05 | (972)824-1591 | | 1680 PRINCE WILLIAM LN. | FRISCO, TX 75034 |
GEN. CONTR. | PARTHENON HOMES X- 06/05 | (972)824-1591 | | 1680 PRINCE WILLIAM LN. | FRISCO, TX 75034 |
MECH. CTR. | KRUGERS HEAT'G & A/C X-06/0 | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | DALLAS PLUMBING CO (PLUMBING) | (214)340-6300 | | P.O. BOX 551648 | DALLAS, TX 75355 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
11/9/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/1/2017
| | 11/1/2017 | |
More Info
|
BACKFLOW | APPROVED |
6/25/2006
| | 6/25/2006 | |
More Info
|
There are currently no reviews on this record.