Permit Info
Short Description:
bf 07-0563 CNEW / GOODYEAR
Expiration Date:
1/10/2012
Notes:
1- CONTINGENT UPON P+Z & CIVIL ENGG APPROVALS OF FINAL SITE PLAN, COMPLIANCE TO BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- DUMPSTER ENCLOSURE TO CONFORM TO CITY CRITERIA FOR SIZE, LAYOUT AND LOCATION. OVERALL SYSTEM TO BE APPROVED BY THE ENVIRONM'L SVCS DEPT (972-335-5519) PRIOR STARTING ANY CONSTRUCTION. (FINAL SOLUTION MUST BE SUBMITTED FOR APPROVAL WITHOUT DIMINISH THE REQ'D NUMBER OF PKG SPACES: 3 EACH BAY +1 EACH EMPLOYEE, UNLESS OTHERWISE CONCEDED IN WRITING BY P+Z).
3- SUBMIT ENGG LETTER AS CONFIRMATION THAT STRUCT'L DESIGN IS BASED ON 2000 IBC, 90 MPH WIND, EXPOSURE C, IMPORTANCE FACTORS AS PER TABLE 1604.5 IBC OR BETTER ACCORDING TO STRUCT'L ENGR'S ANALYSIS OF SOIL REPORT.
4- DO NOT USE GYP. BD LESS THAN 5/8" THICK AS TYPICALLY REQ'D FOR COMMERCIAL PROJECTS.
5- NO MECH'L EQUIPMENTS OR ITEM TO BE PLACED ON ROOF OTHER THAN SMALL VENTS OR FLUES WHEN APPROVED BY INSPECTORS AND PAINTED TO MATCH ROOF COLOR.
6-IECC MAX. SHGC=0.4 AND U=0.7 EXTERIOR GLAZING (WITH PREFERENCE FOR DOUBLE PANE GLASS) & CONFORMING TO SAFETY GLASS REGULATIONS. (SUBMIT MANUF. DOCUMENTATION).
7- EXTERIOR MASONRY WALLS TO HAVE ADDITIONAL R-5 MIN. INSUL. BOARD IN WALL CAVITY TO COMPENSATE FOR THE UNINSULATED CMU CELLS THAT HAVE BEEN FILLED WITH REINFORCED CONCRETE. RECOMMENDED TOTAL WALL THICKNESS=13" (USING NOM. 4" SIZE BRICK AND MC13X31.8 CHANNELS @ OVERHEAD DOOR OPENIGS).
8- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
(9/16/2005 08:25 SEL) GC PAID 9/15 $2,292.56. NEED $ 630.00 MORE FOR PERMIT TO BE RELEASED.
(9/19/2005 12:31 SEL) called GC @ 214-503-3400 to inform of $630.00 and permit is on Hold.
bf 07-0563 CNEW / GOODYEAR
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PLANTATION ADDITION (GOODYEAR)
|
| OWNER | D EDWARD MOORE INVESTMENTS INC | (514)795-8640 | | 5601 COURTYARD DR | AUSTIN, TX |
| MAIL TO | D EDWARD MOORE INVESTMENTS INC | (514)795-8640 | | 5601 COURTYARD DR | AUSTIN, TX |
| APPLICANT | A & A GENERAL CONTRACTOR, INC | (214)660-8170 | | 9888 FERGUSON # 159 | DALLAS, TX 75228 |
| CONTRACTOR | A & A GENERAL CONTRACTOR, INC | (214)660-8170 | | 9888 FERGUSON # 159 | DALLAS, TX 75228 |
| ELECT. CTR. | GARDNER ELECTRICAL | (972)932-3953 | | P.O. BOX 886 | KAUFMAN, TX 75142 |
| GEN. CONTR. | A & A GENERAL CONTRACTOR, INC | (214)660-8170 | | 9888 FERGUSON # 159 | DALLAS, TX 75228 |
| IRRIGATION | ACOSTA'S IRRIGATION x-9/06 | (214)460-8662 | | 603 ENGLISH STREET | IRVING, TX 75061 |
| MECH. CTR. | D & M MECHANICAL X-11/05 | (972)271-1225 | | 2625 NATIONAL CIRCLE | GARLAND, TX 75041 |
| PLUM. CONT. | PRO TECH PLUMBING | (903)447-0901 | | 824 BRIGGS BLVD | POINT, TX 75472 |
|
| BACK FLOW FORM REVIEW |
$75.00
|
1/13/2011
|
| Total Fees |
|
Charged: $75.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
1/10/2011
| | 1/10/2011 | |
More Info
|
| BACKFLOW | APPROVED |
1/10/2011
| | 1/10/2011 | |
More Info
|
| BACKFLOW | APPROVED |
1/10/2011
| | 1/10/2011 | |
More Info
|
| BACKFLOW | APPROVED |
4/11/2006
| | 4/11/2006 | |
More Info
|
| BACKFLOW | APPROVED |
5/4/2005
| | 5/4/2005 | |
More Info
|
There are currently no reviews on this record.