2864 A/C, 3295 SF, SFR / 2 STORY
Notes:
2864 A/C, 3295 SF, SFR / 2 STORY
2/8/2005 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
* 2ND LEVEL WITH 2 BDRMS, 1 BATH, AND GAME ROOM.
Parcel Info
City/State/Zip:
TX, 75034
Subdivision:
KING'S GARDEN #02
|
OWNER | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
APPLICANT | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
CONTRACTOR | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
ELECT. CTR. | LANEHART ELECTRIC | ()- | | 2411 RIVERHILL | IRVING, TX 75061 |
GEN. CONTR. | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
IRRIGATION | NORTH TEXAS LAWN & LANDSCAPE | (972)240-8082 | | P.O. BOX 2140 | ROCKWALL, TX 75087 |
MECH. CTR. | RELIANT A/C X-6/2005 | (972)864-9688 | | P.O. BOX 14849 | FT WORTH, TX 76117 |
PLUM. CONT. | ENTERPRISE PLUMBING X-1/05 | (972)231-2860 | | 900 ALPHA #430 | RICHARDSON, TX 75081 |
Total Fees |