Permit Info
Short Description:
2506 AC, 3084 SQ FT, SFR / 2 STORY
Notes:
2506 AC, 3084 SQ FT, SFR / 2 STORY
2/3/2005 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
11. BEAMS=10"W X 29"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
32. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(02/03/2005 09:54 JC)Driller piers : (5) #4 (or) (4) #5 vertical rebar.
Parcel Info
City/State/Zip:
TX, 75034
Subdivision:
TRAILS #08, THE
|
| OWNER | ASHTON DALLAS RESIDENTIAL | (972)490-3255 | | 13800 MONTFORT DR. #100 | DALLAS, TX 75240-1396 |
| APPLICANT | ASHTON DALLAS RESIDENTIAL | (972)490-3255 | | 13800 MONTFORT DR. #100 | DALLAS, TX 75240-1396 |
| CONTRACTOR | ASHTON DALLAS RESIDENTIAL | (972)490-3255 | | 13800 MONTFORT DR. #100 | DALLAS, TX 75240-1396 |
| ELECT. CTR. | HOUSTON STAFFORD ELECTRIC X- 1 | (972)463-1455 | | 2500 CHANDLER DR. | ROWLETT, TX 75088 |
| GEN. CONTR. | ASHTON DALLAS RESIDENTIAL | (972)490-3255 | | 13800 MONTFORT DR. #100 | DALLAS, TX 75240-1396 |
| IRRIGATION | LAKESIDE IRRIGATION X- 5/2006 | (972)722-8020 | | 504 WILLOW SPRINGS DR. | HEATH, TX 75032 |
| MECH. CTR. | RELIANT A/C X-07/06 | (972)864-9688 | | P.O. BOX 14849 | FT WORTH, TX 76117 |
| PLUM. CONT. | CHRISTIANSON PLUMBING X-04/06 | (972)446-3131 | | P.O. BOX 117557 | CARROLLTON, TX 75011 |
| Total Fees |
|
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.