Permit Info
Short Description:
3847 AC, 4648 SF, SFR / 2 STORY
Notes:
3847 AC, 4648 SF, SFR / 2 STORY
6/6/2005 12:00:00 AM
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
31. SIDING OVER MASONRY AT SECOND STORY NOT ALLOWED.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
2ND LEVEL: 3 BDRM. 2 BA. GAME RM.
FRONT ELEVATION AT WINDOWS, USE HARDI-LAP SIDING, NOT CEDAR
ALL TRIM MUST BE CEMENTITIOUS PRODUCT AND/OR ENG. TREATED WOOD.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
TRAILS #5B THE
|
OWNER | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
APPLICANT | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
ELECT. CTR. | FOX ELECTRIC X-12/05 | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
HERS PROVIDE | C & C ENGINEERING (H.E.R.S. PR | (972)680-2164 | ENERGY@CNCENG.COM | 5608 MALVEY SUITE 100 | FT. WORTH, TX 76107 |
MECH. CTR. | BILL JOPLIN'S COMPRESSOR SRVC | (972)569-8339 | | 301 E. MIDWAY STREET | McKINNEY, TX 75069 |
PLUM. CONT. | FRITZ PLUMBING (PLUM) X-1/06 | (972)335-3560 | | P.O. BOX 194 | FRISCO, TX 75034 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.
There are currently no reviews on this record.