Permit Info
Short Description:
3470 AC, 4204 SQ FT, SFR / 2 STORY
Notes:
3470 AC, 4204 SQ FT, SFR / 2 STORY
4/23/2003 12:00:00 AM
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10.BEAMS=10"W X 28"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
31. SIDING OVER MASONRY AT SECOND STORY NOT ALLOWED.
33. MEDIA ROOM WITH STORAGE CLOSET MUST HAVE OPERABLE WINDOW.
46. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
64. ATTIC VENTILATION PER IRC R.806.2.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
FAIRWAYS, THE #02
|
OWNER | DREES CUSTOM HOMES X-05/03 | (972)953-4500 | | 6051 STATE HIGHWAY #161 | IRVING, TX 75038 |
APPLICANT | DREES CUSTOM HOMES X-05/03 | (972)953-4500 | | 6051 STATE HIGHWAY #161 | IRVING, TX 75038 |
CONTRACTOR | DREES CUSTOM HOMES X-05/03 | (972)953-4500 | | 6051 STATE HIGHWAY #161 | IRVING, TX 75038 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | DREES CUSTOM HOMES X-05/03 | (972)953-4500 | | 6051 STATE HIGHWAY #161 | IRVING, TX 75038 |
IRRIGATION | CHOATE IRRIGATION | ()- | | | |
MECH. CTR. | ADVENT AIR CONDITIONING X-1/04 | (972)221-4373 | | 500 S. KEALY | LEWISVILLE, TX 75057 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/22/2003
| | 10/22/2003 | |
More Info
|
There are currently no reviews on this record.