5/6/2003 12:00:00 AM
1. ***ENERGY STAR***
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
8. BEAMS=10"W X 24"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
33. MEDIA ROOM WITH STORAGE CLOSET MUST HAVE OPERABLE WINDOW.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. STRUCTURAL COL'S MUST BE A MIN. OF 4" X 4" WOOD (OR) 3" O.D. STEEL
52. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING.
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
64. ATTIC VENTILATION PER IRC R.806.2.
(05/06/2003 14:55 JC)Correct right elev. at 2nd. floor to 100% masonry.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
HUNTERS CREEK #07
|
OWNER | HIGHLAND HOMES | (972)562-3300 | | 12850 HILLCREST #200 | DALLAS, TX 75230 |
APPLICANT | HIGHLAND HOMES | (972)562-3300 | | 12850 HILLCREST #200 | DALLAS, TX 75230 |
CONTRACTOR | HIGHLAND HOMES | (972)562-3300 | | 12850 HILLCREST #200 | DALLAS, TX 75230 |
ELECT. CTR. | FUSION ELECTRIC LLC X-06/03 | (972)347-2387 | | 300 W BROADWAY BLDG #8 / P. O. | PROSPER, TX 75078 |
GEN. CONTR. | HIGHLAND HOMES | (972)562-3300 | | 12850 HILLCREST #200 | DALLAS, TX 75230 |
H.E.R.S. PRO | C & C ENGINEERING X-04/04 | (972)680-2164 | | 12021 PLANO ROAD, SUITE 190 | DALLAS, TX 75243 |
MECH. CTR. | KRUGERS HEAT'G & A/C X-03/03 | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |