Permit Info
Short Description:
3189 AC, 3677 SQ FT, SFR / 2 STORY
Notes:
3189 AC, 3677 SQ FT, SFR / 2 STORY
6/9/2003 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 26"D.
39. 1 HOUR FIRE WALL ASSEMBLY REQ'D - SUBMIT DESIGN PRIOR TO WALL CONSTRUCTION.
41. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
45. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
51. CSST GAS PIPING PROHIBITED IN FRISCO.
59. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
60. WEBB FLOOR JOIST SYSTEMS AND ROOF TRUSS SYSTEMS MUST BE ENGINEERED (SEALED AND SIGNED AND APPROVED BY THE ENGINEER OF RECORD PRIOR TO SUBMITTAL FOR A BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
SADDLEBROOK VILLAGE #01
|
OWNER | MERCEDES HOMES | (972)910-9300 | | 11494 LUNA ROAD, SUITE #210 | FARMERS BRANCH, TX 75234 |
APPLICANT | MERCEDES HOMES | (972)910-9300 | | 11494 LUNA ROAD, SUITE #210 | FARMERS BRANCH, TX 75234 |
CONTRACTOR | MERCEDES HOMES | (972)910-9300 | | 11494 LUNA ROAD, SUITE #210 | FARMERS BRANCH, TX 75234 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | MERCEDES HOMES | (972)910-9300 | | 11494 LUNA ROAD, SUITE #210 | FARMERS BRANCH, TX 75234 |
IRRIGATION | RK Greenery, Inc | ()- | | | |
MECH. CTR. | RYMIRE ENGINEERING X-04/03 | (972)620-3500 | | 2818 SATSUMA | DALLAS, TX 75226 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/6/2003
| | 10/6/2003 | |
More Info
|
There are currently no reviews on this record.