4718 AC, 5838 SQ FT, SFR / 2 STORY
Notes:
4718 AC, 5838 SQ FT, SFR / 2 STORY
3/16/2004 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONEBRIAR COUNTRY CLUB ESTATE
|
| OWNER | MICHAEL GIUNTA | (469)374-9994 | | 5920 SAINTSBURY #124 | THE COLONY, TX 75056 |
| APPLICANT | CLASSICAL CUSTOM HOMES X- 3/04 | (972)208-4098 | | P.O. BOX 863809 | PLANO, TX 75086 |
| CONTRACTOR | CLASSICAL CUSTOM HOMES X- 3/04 | (972)208-4098 | | P.O. BOX 863809 | PLANO, TX 75086 |
| ELECT. CTR. | ELITE ELECTRIC X-11/04 | (972)880-9880 | | 9796 FM 1565 | TERRELL, TX 75160 |
| GEN. CONTR. | CLASSICAL CUSTOM HOMES X- 3/04 | (972)208-4098 | | P.O. BOX 863809 | PLANO, TX 75086 |
| IRRIGATION | IRRIGATION PLUS X-5/2005 | (940)321-5389 | | 2401 LULA CT | CORINTH, TX 76210 |
| MECH. CTR. | HOUK AIR CONDITIONING X-3/04 | (817)265-1191 | | 128 FAIRVIEW | ARLINGTON, TX 76010 |
| PLUM. CONT. | RIDDELL PLUMBING, INC.-EXP 08/ | (214)682-4860 | | P O BOX 870517 | MESQUITE, TX 75187 |
| Total Fees |
|
Charged: $0.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
11/18/2004