Permit Info
Short Description:
2839 A/C, 3561 SF, SFR / 2 STORY
Notes:
2839 A/C, 3561 SF, SFR / 2 STORY
4/4/2005 12:00:00 AM
1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
9. BEAMS=10"W X 26"D.
23. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
32. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
A) 2ND LEVEL: 3 BDRM. 1 BA. & GAME RM.
Parcel Info
City/State/Zip:
TX, 75035
Subdivision:
PANTHER CREEK ESTATES #04
|
OWNER | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
APPLICANT | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
CONTRACTOR | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
ELECT. CTR. | HOUSTON STAFFORD ELECTRIC X- 1 | (972)463-1455 | | 2500 CHANDLER DR. | ROWLETT, TX 75088 |
GEN. CONTR. | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
IRRIGATION | GP & E (IRRIGATION) | (972)335-7373 | | 103 FM 423 | LITTLE ELM, TX 75068 |
MECH. CTR. | AIRTRON INC. X-7 | (972)272-9633 | | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | L & S PLUMBING X- 06/05 | (972)480-8272 | | 917 N. BOWSER | RICHARDSON, TX 75081 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.