Permit Info
Short Description:
3981 AC, 4844 SQ FT, SFR / 2 STORY
Notes:
3981 AC, 4844 SQ FT, SFR / 2 STORY
10/12/2004 12:00:00 AM
1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
6. BEAMS=8"W X 28"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(10/12/2004 14:19 JC)Grade Beams: (2) #4 rebar in all beam bottoms that do not contain beam strands. 2nd. floor with (3) bedrooms, (2) baths, game and media rooms.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONE CREEK VILLAGE #01
|
OWNER | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
APPLICANT | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
CONTRACTOR | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC X-8/2005 | (214)607-1934 | | 5141 GORDON SMITH | ROWLETT, TX 75088 |
GEN. CONTR. | SOTHERBY HOMES | (214)837-2588 | | 2400 DALLAS PARKWAY #580 | PLANO, TX 75093 |
IRRIGATION | CHOATE IRRIGATION X-01/31/2005 | (972)306-0755 | | P O BOX 118114 | CARROLLTON, TX 75011 |
MECH. CTR. | KRUGERS HEAT'G & A/C | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | C & R PLUMBING CO X-8/05 | (972)424-1334 | | 2206 HIGH POINT | CARROLLTON, TX 75007 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/19/2005
| | 3/19/2005 | |
More Info
|
There are currently no reviews on this record.