Permit Info
Short Description:
2951 AC, 3534 SQ FT, SFR \ 2 STORY
Notes:
2951 AC, 3534 SQ FT, SFR \ 2 STORY
5/24/2004 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC
(5/29/2004 07:36 DEB) BUILDERS CHECK WAS SHORT $54...ADJUSTED BUILDING PERMIT FEE FROM $1,598.75 TO $1,544.75.
CHECK # 1149 - $2,039.27
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
FAIRWAYS #03, THE
|
OWNER | REIG BUILDERS | (972)395-7502 | | PO BOX 111726 | CARROLLTON, TX 75011 |
APPLICANT | REIG BUILDERS | (972)395-7502 | | PO BOX 111726 | CARROLLTON, TX 75011 |
CONTRACTOR | REIG BUILDERS | (972)395-7502 | | PO BOX 111726 | CARROLLTON, TX 75011 |
ELECT. CTR. | MASTER ELECTRICAL SYSTEM-EXP 0 | (972)323-9243 | | P O BOX 112608 | CARROLLTON, TX 75011 |
GEN. CONTR. | REIG BUILDERS | (972)395-7502 | | PO BOX 111726 | CARROLLTON, TX 75011 |
IRRIGATION | HALL'S AUTOMATIC SPRINKLER | (972)285-9088 | | 7100 CR 4064 | KEMP, TX 75143 |
MECH. CTR. | RELIANT A/C -EXP 06/04 | (972)864-9688 | | P.O. BOX 14849 | FT WORTH, TX 76117 |
PLUM. CONT. | KIDD PLUMBING COMPANY X- 3/05 | (817)481-7200 | | P.O. BOX 2284 | GRAPEVINE, TX 76099 |
Total Fees |