Permit Info
Short Description:
2787 AC, 3367 SF, 2 STORY
Approved Date:
12/21/2023
Expiration Date:
12/4/2024
Notes:
12/20/2023 9:19:25 AM
Foundation Beam Size: 28"D X 10"W / 32"D X 10"W
STEP RISERS (VERTICAL PORTION OF STEP) ASSOCIATED WITH FRONT PORCHES AND STOOPS SHALL BE CLAD IN BRICK OR NATURAL STONE PER PD 277.
ALL PH40 HOMES TO HAVE A FRONT PORCH OR PATIO (COVERED OR UNCOVERED) MEASURING A MINIMUM OF 7' X 10', OR A STOOP MEASURING A MINIMUM OF 24SF.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
GROVE FRISCO PHASE 8, THE (CFR)
|
| APPLICANT | Liliana Moton | (972)410-4691 | lmoton@alhltd.com | 4400 State Highway 121 | Lewisville, TX 75056 |
| OWNER | FM 3537 LLC NASH | ()- | | 733 8TH AVE | SAN DIEGO, CA 92101-6407 |
| CONTRACTOR | AMERICAN LEGEND HOMES | (972)410-5701 | LMOTON@ALHLTD.COM | 2540 KING ARTHUR BLVD | LEWISVILLE, TX 75056 |
| HERS PROVIDE | The Nelrod Company dba Fox Energy Specialists | (817)546-0160 | info@foxenergyspecialists.com | 3301 WEST FWY. | FORT WORTH, TX 76107 |
| STRUCT ENG | ERIC L DAVIS ENG INC (STRUCT) | (972)564-0592 | kime@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
| ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES LLC | (512)402-4563 | DALLAS@IN-CHARGE-ELECTRIC.COM | 501 VALLEY RIDGE BLVD. STE A | LEWISVILLE, TX 75057 |
| MECH. CTR. | HOUK AIR CONDITIONING | (817)543-5807 | dfwpermits@houkac.com | 833 111TH STREET | ARLINGTON, TX 76011 |
| PLUM. CTR. | ENTERPRISE PLUMBING OF TX | (972)231-2860 | cindyz@enterplumb.com | 900 ALPHA STE 430 | RICHARDSON, TX 75081 |
|
| 1 INCH PD METER |
$540.00
|
12/21/2023
|
| WATER METER DEPOSIT |
$150.00
|
12/21/2023
|
| DRYWALL RES 04/02/2024 CMM2 |
$30.00
|
4/2/2024
|
| FLATWORK RES 04/08/2024 CMM2 |
$30.00
|
6/5/2024
|
| ELECT FINAL RES 05/03/2024 CMM2 |
$30.00
|
6/5/2024
|
| PERCENT CREDIT CARD FEE |
$2.40
|
4/2/2024
|
| PERCENT CREDIT CARD FEE |
$1.20
|
6/5/2024
|
| 2NDS AND FRAMING 03/13/2024 JDR |
$30.00
|
4/2/2024
|
| 2NDS AND FRAMING 03/15/2024 JDR |
$30.00
|
4/2/2024
|
| PTO AND MECH ROUGH 03/11/2024 JWR |
$30.00
|
4/2/2024
|
| AUTO PROCESSING FEE |
$6.00
|
12/15/2023
|
| FENCE FEE |
$20.00
|
12/21/2023
|
| Z-FIELDS REIMBURSEMENT FEE |
$0.00
|
|
| RESIDENTIAL NEW PERMIT FEE |
$1,184.78
|
12/21/2023
|
| RESIDENTIAL FEE |
$101.01
|
12/21/2023
|
| RESIDENTIAL MECHANICAL FEE |
$128.50
|
12/21/2023
|
| RESIDENTIAL NEW APPLICATION FEE |
$300.00
|
12/15/2023
|
| RESIDENTIAL PLUMBING FEE |
$164.00
|
12/21/2023
|
| SEWER IMPACT FEE |
$0.00
|
|
| THOROUGHFARE IMPACT FEE |
$1,337.00
|
12/21/2023
|
| WATER IMPACT FEE |
$2,120.00
|
12/21/2023
|
| Total Fees |
|
Charged: $6,234.89
Balance Due: $0.00
|
|
| CO AND BUILD FINAL | APPROVED |
6/7/2024
| | 6/7/2024 | |
More Info
|
| CO AND BUILD FINAL | RES FAILED |
6/6/2024
| | 6/6/2024 | |
More Info
|
| PLUMB MECH FINAL | APPROVED |
6/4/2024
| | 6/4/2024 | |
More Info
|
| PLUMB MECH FINAL | RES FAILED |
6/3/2024
| | 6/3/2024 | |
More Info
|
| UTILITIES INSPECTION | APPROVED |
5/31/2024
| | 6/3/2024 | |
More Info
|
| ELECT FINAL RES | APPROVED |
5/7/2024
| | 5/7/2024 | |
More Info
|
| GAS RELEASE | APPROVED |
5/3/2024
| | 5/3/2024 | |
More Info
|
| ELECT FINAL RES | RES FAILED |
5/3/2024
| | 5/3/2024 | |
More Info
|
| FLATWORK RES | APPROVED |
4/10/2024
| | 4/10/2024 | |
More Info
|
| FLATWORK RES | RES FAILED |
4/8/2024
| | 4/8/2024 | |
More Info
|
| DRYWALL RES | APPROVED |
4/3/2024
| | 4/3/2024 | |
More Info
|
| DRYWALL RES | RES FAILED |
4/2/2024
| | 4/2/2024 | |
More Info
|
| BRICKWALL TIES RES | APPROVED |
3/27/2024
| | 3/27/2024 | |
More Info
|
| INSULATION RES | APPROVED |
3/26/2024
| | 3/26/2024 | |
More Info
|
| INSULATION RES | CANCELLED |
3/25/2024
| | 3/25/2024 | |
More Info
|
| 2NDS AND FRAMING | APPROVED |
3/19/2024
| | 3/19/2024 | |
More Info
|
| 2NDS AND FRAMING | RES FAILED |
3/15/2024
| | 3/15/2024 | |
More Info
|
| 2NDS AND FRAMING | RES FAILED |
3/13/2024
| | 3/13/2024 | |
More Info
|
| PTO AND MECH ROUGH | APPROVED |
3/12/2024
| | 3/12/2024 | |
More Info
|
| PTO AND MECH ROUGH | RES FAILED |
3/11/2024
| | 3/11/2024 | |
More Info
|
| SLAB RES | APPROVED |
2/9/2024
| | 2/9/2024 | |
More Info
|
| PLUMBING ROUGH-IN | APPROVED |
2/5/2024
| | 2/5/2024 | |
More Info
|
| SET 1 PD METER | APPROVED |
1/30/2024
| | 1/30/2024 | |
More Info
|
| T-POLE RES | APPROVED |
1/25/2024
| | 1/25/2024 | |
More Info
|
| METER PAYMENT | APPROVED |
| | 12/21/2023 | |
More Info
|