Permit Info
Short Description:
2664 AC 3444 SF, 2 STORY
Expiration Date:
11/11/2023
Notes:
1/14/2022 10:35:08 AM
Foundation Beam Size: 10"W X 28"D
OPEN FENCING REQUIRED ADJACENT TO OPEN SPACE
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
PRESTON HILLS ADDITION - PHASE 2 (CFR)
|
| APPLICANT | Hannah Rodgers | (214)614-8664 | permitdocs@megatelhomes.com | 2101 Cedar Springs Rd #700 | Dallas, TX 75201 |
| OWNER | FRISCO 113 LLC CTMGT | (214)396-4234 | permitdocs@megatelhomes.com | 1800 VALLEY VIEW LN STE 300 | DALLAS, TX 75234-8945 |
| CONTRACTOR | MEGATEL HOMES INC | (214)614-8664 | PERMITDOCS@MEGATELHOMES.COM | 2101 Cedar Springs Rd #700 | Dallas, TX 75201 |
| ENGINEER | ERIC L DAVIS ENG INC (STRUCT) | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
| HERS PROVIDE | ARCXIS | (713)930-0486 | msmith1@arcxis.com | 19450 State Highway 249, Ste. 300 | HOUSTON, TX 77070 |
| STRUCT ENG | ERIC L DAVIS ENG INC (STRUCT) | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
| ELECT. CTR. | IES RESIDENTIAL INC (ELEC) | (972)562-7724 | brian.hartley@ies-co.com | 713 TOWER LANE STE A | MCKINNEY, TX 75069 |
| MECH. CTR. | HOUK AIR CONDITIONING | (817)543-5809 | JSINCLAIR@HOUKAC.COM | 833 111TH STREET | ARLINGTON, TX 76011 |
| PLUM. CTR. | CATHEDRAL PLUMBING OF TEXAS LLC | (972)446-2500 | WENDI.M@CATHEDRALPLUMBINGTX.COM | 1451 HALSLEY WAY | CARROLTON, TX 75007 |
|
| PLAN REVIEW FEE |
$50.00
|
6/3/2022
|
| GAS RELEASE 03/20/2023 DOT |
$30.00
|
3/23/2023
|
| FLATWORK RES 03/22/2023 DWF |
$30.00
|
3/23/2023
|
| CREDIT CARD FEE |
$12.00
|
4/22/2022
|
| PERCENT CREDIT CARD FEE |
$2.40
|
12/8/2022
|
| PERCENT CREDIT CARD FEE |
$0.20
|
1/4/2023
|
| PERCENT CREDIT CARD FEE |
$1.20
|
1/19/2023
|
| PERCENT CREDIT CARD FEE |
$1.20
|
3/23/2023
|
| PERCENT CREDIT CARD FEE |
$0.60
|
4/13/2023
|
| REPLACE DAMAGED/UNREADABLE REGISTER |
$500.00
|
4/22/2022
|
| SET 1 PD METER 02/21/2022 BSJ |
$100.00
|
4/22/2022
|
| 1 INCH PD METER |
$450.00
|
1/19/2022
|
| WATER METER DEPOSIT |
$125.00
|
1/19/2022
|
| PLAN REVIEW FEE |
$10.00
|
1/4/2023
|
| AUTO PROCESSING FEE |
$1.00
|
6/3/2022
|
| FENCE FEE |
$20.00
|
1/17/2022
|
| RESIDENTIAL NEW PERMIT FEE |
$1,210.96
|
1/17/2022
|
| RESIDENTIAL FEE |
$103.32
|
1/17/2022
|
| RESIDENTIAL MECHANICAL FEE |
$146.00
|
1/17/2022
|
| RESIDENTIAL NEW APPLICATION FEE |
$300.00
|
1/6/2022
|
| RESIDENTIAL PLUMBING FEE |
$235.00
|
1/17/2022
|
| SEWER IMPACT FEE |
$2,344.00
|
1/17/2022
|
| THOROUGHFARE IMPACT FEE |
$0.00
|
|
| WATER IMPACT FEE |
$0.00
|
|
| 2NDS AND FRAMING 01/13/2023 PJF |
$30.00
|
1/19/2023
|
| 2NDS AND FRAMING 01/18/2023 PJF |
$30.00
|
1/19/2023
|
| GAS RELEASE 04/11/2023 SDC |
$30.00
|
4/13/2023
|
| PTO AND MECH ROUGH 10/11/2022 SME2 |
$30.00
|
12/8/2022
|
| PTO AND MECH ROUGH 11/09/2022 SME2 |
$30.00
|
12/8/2022
|
| PTO AND MECH ROUGH 11/23/2022 SME2 |
$30.00
|
12/8/2022
|
| PTO AND MECH ROUGH 10/19/2022 SMH |
$30.00
|
12/8/2022
|
| Total Fees |
|
Charged: $5,882.88
Balance Due: $0.00
|
|
| CO AND BUILD FINAL | APPROVED |
5/15/2023
| | 5/15/2023 | |
More Info
|
| PLUMB MECH FINAL | APPROVED |
5/12/2023
| | 5/12/2023 | |
More Info
|
| PLUMB MECH FINAL | RES FAILED |
5/10/2023
| | 5/10/2023 | |
More Info
|
| PLUMB MECH FINAL | CANCELLED |
5/8/2023
| | 5/8/2023 | |
More Info
|
| PLUMB MECH FINAL | CANCELLED |
5/4/2023
| | 5/4/2023 | |
More Info
|
| UTILITIES INSPECTION | APPROVED |
4/24/2023
| | 4/25/2023 | |
More Info
|
| GAS RELEASE | APPROVED |
4/14/2023
| | 4/14/2023 | |
More Info
|
| ELECT FINAL RES | APPROVED |
4/12/2023
| | 4/12/2023 | |
More Info
|
| ELECT FINAL RES | RES FAILED |
4/11/2023
| | 4/11/2023 | |
More Info
|
| GAS RELEASE | RES FAILED |
4/11/2023
| | 4/11/2023 | |
More Info
|
| FLATWORK RES | APPROVED |
3/30/2023
| | 3/30/2023 | |
More Info
|
| FLATWORK RES | RES FAILED |
3/22/2023
| | 3/22/2023 | |
More Info
|
| GAS RELEASE | RES FAILED |
3/21/2023
| | 3/20/2023 | |
More Info
|
| BRICKWALL TIES RES | APPROVED |
2/13/2023
| | 2/13/2023 | |
More Info
|
| DRYWALL RES | APPROVED |
2/3/2023
| | 2/3/2023 | |
More Info
|
| INSULATION RES | APPROVED |
1/27/2023
| | 1/27/2023 | |
More Info
|
| 2NDS AND FRAMING | APPROVED |
1/23/2023
| | 1/23/2023 | |
More Info
|
| 2NDS AND FRAMING | RES FAILED |
1/18/2023
| | 1/18/2023 | |
More Info
|
| 2NDS AND FRAMING | RES FAILED |
1/13/2023
| | 1/13/2023 | |
More Info
|
| 2NDS AND FRAMING | RES FAILED |
1/11/2023
| | 1/11/2023 | |
More Info
|
| 2NDS AND FRAMING | CANCELLED |
1/9/2023
| | 1/9/2023 | |
More Info
|
| 2NDS AND FRAMING | RES FAILED |
12/15/2022
| | 12/15/2022 | |
More Info
|
| PTO AND MECH ROUGH | APPROVED |
12/9/2022
| | 12/9/2022 | |
More Info
|
| PTO AND MECH ROUGH | RES FAILED |
11/23/2022
| | 11/23/2022 | |
More Info
|
| PTO AND MECH ROUGH | RES FAILED |
11/9/2022
| | 11/9/2022 | |
More Info
|
| PTO AND MECH ROUGH | RES FAILED |
10/19/2022
| | 10/19/2022 | |
More Info
|
| PTO AND MECH ROUGH | RES FAILED |
10/11/2022
| | 10/11/2022 | |
More Info
|
| SET 1 PD METER | |
3/25/2022
| | | |
More Info
|
| SLAB RES | APPROVED |
3/25/2022
| | 3/25/2022 | |
More Info
|
| WATER REGISTER | APPROVED |
3/25/2022
| 9:45 AM | 3/25/2022 | |
More Info
|
| PLUMBING ROUGH-IN | APPROVED |
3/16/2022
| | 3/16/2022 | |
More Info
|
| SET 1 PD METER | APPROVED |
3/1/2022
| 8:30 AM | 3/1/2022 | |
More Info
|
| SET 1 PD METER | WM NOT READY |
2/21/2022
| 8:30 AM | 2/21/2022 | |
More Info
|
| T-POLE RES | APPROVED |
2/21/2022
| | 2/21/2022 | |
More Info
|
| METER PAYMENT | APPROVED |
1/19/2022
| | 1/19/2022 | |
More Info
|
There are currently no reviews on this record.