Notes:
4/28/2020 3:24:30 PM
*******REMOVE DAMAGE BRICK FROM EXTERIOR AND CALL FOR INSPECTIONS FOR FRAMING / IF FRAMING IS DAMAGE NEED TO SUBMIT PLANS ********
BRICK / WALL TIES INSPECTION AT 4' HIGH.
1) Clean mortar from behind brick
2) Remove every 3rd brick bottom row
3) Moisture barrier for OSB R703.2
4) Protect Romex Table E3701.4
5) Poly under brick R703.7.5
6) Brick ties R703.7.4
7) Weep holes R703.7.6, R703.7.2.1
132. * ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE.
146. *** NO ELECTRICAL OR PLUMBING PERMIT REQUESTED OR ISSUED ***
150. ALL FACADES (EXTERIOR) MATERIALS MUST REFLECT EARLY 20TH CENTURY TEXAS ARCHITECTURAL STYLES SAME AS THE EXISTING STRUCTURE.
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.
163. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.