Notes:
5/14/2020 3:39:01 PM
Patio Cover & Grill & FIRE PIT
1- All work performed must meet the 2018 IRC standards and abide by the City of Frisco comprehensive Zoning Ordinance, and all other city Ordinances.
2- Need a flatwork inspection before the pour.
3- May not adversely affect drainage of neighboring properties.
4- Double underlayment required on composition roofs with a 4:12 pitch roof or less. Minimum
2/12 pitch for composition shingles.
5- Outside of post cannot encroach the rear yard setback, up to three foot over-hang is allowed. Can encroach rear build line if 10 feet away from the main structure.
6- R905.2.2 slope: asphalt shingles shall be used only on roof slope of two units vertical in 12 units horizontal (2:12) or greater. for roof slopes from two units vertical in 12 units horizontal (2:12) up to four units vertical in 12 units horizontal (4:12) double underlayment application is required in accordance with section r905.11
8- Fireplace, fire pit, , sink, etc) not requested or permitted.
9- Lag bolt must penetrate main house stud min 1 ½".
10- May not intrude on side yard setbacks.
Grill
2- May not intrude on side yard setbacks. exception: may encroach up to 7 ft on corner lots.
3- A gas line pressure test is required when adding gas to an outdoor appliance.
4- Subject to field inspection approval. call (972) 292-5386 for inspection.
5- Must be 3’ from side property line once past rear build line. must be 10’ from rear property line.
11- Subject to field inspection approval. call (972) 292-5386 for inspection.
12- City of Frisco approval is not in lieu of homeowner association HOA requirements. reference HOA bylaws for subdivision requirements.
5/14/2020 3:39:09 PM
Fire Pit
1- All work performed must meet the 2018 IRC standards.
2- May not intrude on side or rear yard setbacks.
3- Acceptable fire extinguishing device must be readily accessible.
4- Fire pits shall have a minimum distance of fifteen feet (15') from the main structure and ten feet (10') from any combustible item.
5- Subject to field inspection approval. Call (972) 292-5386 for inspection.
6- City of Frisco approval is not in lieu of homeowner association HOA requirements. Reference HOA bylaws for subdivision requirements.
All fire features to be considered as appliances shall be tested and listed by a NRTL as compliant with ANSI z21.42 or z21.97, otherwise they shall be considered as open burning fire pits and subject to the setback requirement of the international fire code and comprehensive Zoning Ordinance