Notes:
12/11/2019 2:02:05 PM
NEW FIREPLACE
MUST MEET CLEARANCES FROM PAGE 12-18 FOR FIREPLACE. PICTURE DOES NOT LOOK LIKE YOU MEET CLEARANCE.
NO ELECTRICAL OR PLUMBING
MUST HAVE FRAMING INSPECTIONS DONE
172. * ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS.
176. * VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
177. *MUST MAINTAIN CLEARANCES PER R1001.11 2015 IRC
178. * CHIMNEY MUST MAINTAIN A MINIMUM OF 2' IN CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
179. * FOOTER THICKNESS 12" MIN & WIDTH 6" EACH SIDE OF FIREPLACE WALL.
** A GASLINE PRESSURE TEST IS REQUIRED WHEN ADDING GAS TO A FIREPLACE ADDITION **
173. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.