Notes:
2/20/2019 3:03:40 PM
GARAGE ADDITION.
142. * ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
SEE ENGINEERS DETAIL FOR FRAMING STRUCTURE
146. *** NO PLUMBING PERMIT REQUESTED OR ISSUED ***
151. ***MAY NOT INTRUDE ON SIDE OR REAR YARD SETBACKS.
***100 % MASONRY REQUIREMENTS FOR FIRST FLOOR GARAGE BY ZONING ORDINANCE REQUIREMENT
**SHALL NOT ENCROACH ANY EASEMENTS**
118. *** NEED A FOUNDATION AND FLAT WORK INSPECTION BEFORE THE POUR.
DRIVEWAY EXTENSION
115. * 5' TURNING RADIUS REQUIRED AT THE APPROACH.
116. * 8" DEPTH THE FIRST FOOT IN FROM THE LIP OF THE STREET/ALLEY.
117. * IF METER WITHIN 3' OF DRIVEWAY, NEED TO INSTALL BALLARD.
118. *** NEED A FLAT WORK INSPECTION BEFORE THE POUR. ***
*DRIVEWAY MUST BE THE SAME WIDTH FROM THE PROPERTY LINE TO THE CURB CUT FLARE POINT.
*FLARE POINT TO WIDEN DRIVEWAY MUST BE AT OR BEHIND PROPERTY LINE.
*MAXIMUM WIDTH OF DRIVEWAY FROM THE STREET TO THE PROPERTY LINE IS 24’. BEYOND THE PROPERTY LINE CAN BE UP TO 34 FEET WIDE, ON FRONT ENTRY LOTS AND INCLUDE A REINFORCED CONCRETE TURN-DOWN FOR EROSION CONTROL.
*DRIVEWAY SLAB SHALL BE AT LEAST 24" OR MORE SEPARATION BETWEEN SLAB AND SIDE YARD PROPERTY LINE.*
**MAY NOT ADVERSELY AFFECT DRAINAGE OF NEIGHBORING PROPERTIES**
***ANY WORK DONE IN ROW REQUIRES A SEPARATE PERMIT FROM PUBLIC WORKS.***
MECHANICAL
401. * ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
ELECTRICAL
* ALL WORK PERFORMED MUST MEET THE 2014 NEC AND 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
***WITH THE OPTIONAL ENTRY TO THE MAIN HOUSE AND BEDROOM, ADD CARBON MONOXIDE DETECTOR PROTECTION FROM GARAGE TO MASTER BEDROOM***
01. MINIMUM #12 COPPER CONDUCTORS PERMITTED EXCEPT FOR CONTROLS.
02. NO ALUMINUM WIRE PERMITTED OR #14
113. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.