Permit Info
Short Description:
5296 AC 6562 SF, SFR / 2 STORY
Approved Date:
10/19/2018
Expiration Date:
4/19/2019
Notes:
10/19/2018 9:58:46 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
033. ALL SIDING,TRIM,SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL.
034. RESIDENTIAL STUCCO REQUIRES LATH AND EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. TEMPERED GLASS REQUIRED AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQUIRED AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEAD WALK AND GARAGE DOOR ENHANCEMENT AND TREATMENT PER THE ENCLOSED DETAIL
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
10/19/2018 10:02:21 AM
Grade Beams : exterior 10" w. x 42" deep, interior 10" w. x 36" deep.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
EDGESTONE AT LEGACY PHASE 1
|
| APPLICANT | HUNTINGTON HOMES | (972)789-3500 | bking@hhomesltd.com | SUITE 300 | FRISCO, TX 75035 |
| OWNER | HUNTINGTON HOMES | (972)789-3500 | bking@hhomesltd.com | SUITE 300 | FRISCO, TX 75035 |
| CONTRACTOR | HUNTINGTON HOMES | (972)789-3500 | bking@hhomesltd.com | SUITE 300 | FRISCO, TX 75035 |
| ENGINEER | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
| HERS PROVIDE | FOX ENERGY SPECIALIST / THE NELROD CO | (817)546-0160 | info@foxenergyspecialists.com | | FORT WORTH, TX 76109 |
| STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
| ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES LLC | (972)292-1478 | MATTGOLDBERG@IN-CHARGE-ELECTRIC.COM | | LEWISVILLE, TX T5057 |
| MECH. CTR. | ADVENT AIR CONDITIONING INC | (972)221-4373 | aramon@adventair.com | | LEWISVILLE, TX 75057 |
| PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP INC | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
|
| RESIDENTIAL BUILDING PERMIT FEE |
$2,473.75
|
|
| RESIDENTIAL FEE |
$196.86
|
|
| FENCE FEE |
$20.00
|
|
| RESIDENTIAL PLUMBING FEE |
$336.00
|
|
| RESIDENTIAL MECHANICAL FEE |
$192.00
|
|
| WATER IMPACT FEE |
$1,845.00
|
|
| SEWER IMPACT FEE |
$1,619.00
|
|
| Total Fees |
|
Charged: $6,682.61
Balance Due: $6,682.61
|
There are currently no inspections on this record.
|
| INITIAL REVIEW | HEYVIND CASTILLO | ACCEPTED | 10/9/2018 | 10/9/2018 | 10/23/2018 |
More Info
|
| RESIDENTIAL REVIEW | JIM COTTONE | APPROVED AS NOTED | 10/9/2018 | 10/19/2018 | 10/23/2018 |
More Info
|