Notes:
10/29/2018 9:21:50 AM
BALCONY ADDITION
* ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
BALCONY RAILING SPACING IS 3 3/4" AND RAILING HEIGHT BETWEEN 34'' AND 38'' REQ'D.
BALCONY RAILING SHALL BE ANCHORED TO EXISTING STRUCTURE.
ALL WOOD MUST BE WEATHER TREATED.
ADDITION OF A BALCONY OR ENCLOSURE OF AN EXISTING BALCONY REQUIRES ENGINEERED PLANS AND EVALUATION.
AN ENGINEER'S INSPECTION AND FINAL LETTER OF ACCEPTANCE IS REQ'D.
TEMP'D.GLAZING WHERE REQ'D.
THE METHOD OF ATTACHMENT OF NEW BALCONY TO EXISTING HOME MUST BE VISIBLE AT TIME OF INSPECTION.
SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS
10/29/2018 9:23:10 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
042. TEMPERED GLASS REQUIRED AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQUIRED AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.