Notes:
7/24/2018 8:36:16 AM
100. ARBOR
101. ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE AND ALL OTHER CITY ORDINANCES
102. NEED A FLATWORK INSPECTION BEFORE THE POUR
103. OUTSIDE OF POST CAN NOT ENCROACH THE 10' REAR YARD SETBACK ALLOWED FOR OPEN AIR ARBOR WITH OPEN TOP ROOF, UP TO THREE FOOT OVER-HANG IS ALLOWED
106. LAG BOLT MUST PENETRATE MAIN HOUSE STUD MIN 1 "
107. THE SPACING BETWEEN ARBOR SLATS/RUNNERS SHOULD BE EQUAL TO THE WIDTH OF THE SLAT. EX. 1X 6 BOARD SHOULD HAVE A 6 SPACING
108. MAY NOT INTRUDE ON SIDE YARD SETBACKS
109. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION
110. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS
126. OUTDOOR KITCHEN
127. ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE AND ALL OTHER CITY ORDINANCES
128. MAY NOT INTRUDE ON SIDE YARD SETBACKS. EXCEPTION: MAY ENCROACH UP TO 7 FT ON CORNER LOTS
129. MUST BE 3 FROM SIDE PROPERTY LINE ONCE PAST REAR BUILD LINE. MUST BE 10 FROM REAR PROPERTY LINE
130. A GAS LINE PRESSURE TEST IS REQUIRED WHEN ADDING GAS TO AN OUTDOOR APPLIANCE
131. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION
132. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS
154. GAS ILLUMINATED APPLIANCE
155.ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE AND ALL OTHER CITY ORDINANCES
156. MAY NOT INTRUDE ON SIDE YARD SETBACKS.\u0026nbsp; MAY ENCROACH UP TO 7 FT ON CORNER LOTS
157. AN ANSI Z21.42 / Z21.97 LISTED AND LABELED DEVICE FOR USE WITH GAS COMPOSED OF FACTORY-MADE COMPONENTS ASSEMBLED IN THE FIELD IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTION AND CONDITIONS OF THE LISTING. ILLUMINATING APPLIANCES SHALL FOLLOW THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND REQUIRED CLEARANCES ARE DICTATED BY THE MANUFACTURES INSTRUCTIONS AS INDICATED BY THE LISTING AGENCY THAT TESTED THE APPLIANCE.
158. AN APPROVED GAS ILLUMINATING OR OUTDOOR DECORATIVE APPLIANCE (ANSI Z21.42 / ANSI Z21.97) UP TO 36 IN HEIGHT MAY BE LOCATED IN ANY LOCATION OTHER THAN REQUIRED SIDE YARDS PROVIDED THAT IT IS NO CLOSER TO THE PROPERTY LINE OR COMBUSTIBLES THAN THE RECOMMEND MANUFACTURERS CLEARANCE TO COMBUSTIBLES
159. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION
160. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.
161. A GAS LINE PRESSURE TEST IS REQUIRED WHEN ADDING GAS TO AN OUTDOOR
APPLIANCE