Notes:
7/17/2018 9:21:04 AM
TELLA FIRMA SUSPENDED FOUNDATION POST-TENSION W / PIERS, THIS IS THE NEW STYLE TELLA FIRMA SUSPENDED FOUNDATION. SEE ENGINEERS DETAIL FOR SPEC'S ON PIER DETAIL, CABLE DETAIL, AND PLUMBING DETAIL FOR SLAB PENETRATIONS. ENGINEERS PRE-POUR INSPECTION LETTER OF ACCEPTANCE REQUIRED FOR PIERS AND TELLA FIRMA SUSPENDED FOUNDATION.SINGLE FAMILY RESIDENTIAL ELEVATORS:
1a: SINGLE FAMILY RESIDENTIAL ELEVATORS.A. MUST COMPLY WITH ASME A17.1B. MUST BE INSPECTED Y A QEI-1 CERTIFIED INSPECTOR AFTER THE INSTALLATION IS COMPLETE.C. MUST COMPLY WITH ICC A 117.1 OF THE IBC FOR ACCESSIBILITY.D. A COPY OF THE INSPECTION REPORT MUST BE GIVEN TO THE OWNER AND A COPY IN THE PERMIT PACKET FOR FINAL INSPECTION BY CITY OF FRISCO.E. ALL OF THE ABOVE MUST BE COMPLETE PRIOR TO THE ISSUE OF THE CERTIFICATE OF OCCUPANCY.
2a: DRIVEWAY APPROACH RADIUS AT STREET CURB SHALL NOT ENCROACH SIDE YARD PROPERTY LINE AT THE STREET**
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HEIGHT FROM AVG FINISH GRADE 40'-0".
009. BEAMS=8"W X 26"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
034. RESIDENTIAL STUCCO REQUIRES LATH AND EXPANDED WIRE MESH WITH CEMENT PLASTER.
038. STAIR VERTICAL RISE OF 147(R311.7.3) OR GREATER REQUIRES AN INTERMEDIATE LANDING
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 4 RISERS OR MORE REQUIRE A HANDRAIL
040. TEMPERED GLASS REQUIRED AT STAIR LANDING WINDOW(S).
041. TEMPERED GLASS REQUIRED AT WINDOWS ADJACENT TO STAIRS
042. TEMPERED GLASS REQUIRED AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQUIRED AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS. EMERGENCY/ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF \u003e= 5.7 SQFT. MINIMUM NET CLEAR HEIGHT OF 24" AND NET CLEAR WIDTH OF 20" (GRADE FLOOR OR BELOW \u003e= 5.0SQFT).
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND AND ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN AND INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEAD WALK AND GARAGE DOOR ENHANCEMENT AND TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 3BR, 3BA, LAUNDRY, GAME, MEDIA, COVERED PORCH, WET BAR.