Permit Info
Short Description:
3257 AC, 3982 SF, SFR / 2 STORY
Notes:
1/3/2018 2:30:31 PM
JIM COTTONE
RESIDENTIAL REVIEW
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 4 RISERS OR MORE REQUIRE A HANDRAIL
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
054. LETTERS OF ACCEPTANCE FOR FOUNDATION & FRAME REQUIRED FROM BOTH ENGINEERS FOR CO.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
1/3/2018 2:29:31 PM
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
HOLLYHOCK PHASES 1B & 1C
|
APPLICANT | BRITTON HOMES / PERRY HOMES CO | (972)629-3892 | victoria.haase@brittonhomestexas.com | 9000 Gulf Freeway | Houston, TX 77017 |
OWNER | PERRY HOMES LLC | ()- | | | HOUSTON, TX 77017-7018 |
CONTRACTOR | BRITTON HOMES / PERRY HOMES CO | (972)629-3892 | victoria.haase@brittonhomestexas.com | 9000 Gulf Freeway | Houston, TX 77017 |
ENGINEER | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NELROD CO | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
STRUCT ENG | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
ELECT. CTR. | L & S MECHANICAL (elec) | (214)393-8338 | ASchmidt@lsmech.com | | RICHARDSON, TX 75081 |
MECH. CTR. | L & S MECHANICAL (mech) | (214)393-8338 | ASCHMIDT@lsmech.com | | RICHARDSON, TX 75081 |
PLUM. CONT. | L & S MECHANICAL (elec) | (214)393-8338 | ASchmidt@lsmech.com | | RICHARDSON, TX 75081 |
|
WATER IMPACT FEE |
$426.00
|
|
SEWER IMPACT FEE |
$1,619.00
|
|
THOROUGHFARE IMPACT FEE |
$0.00
|
|
RESIDENTIAL BUILDING PERMIT FEE |
$1,713.75
|
|
FENCE FEE |
$20.00
|
|
RESIDENTIAL FEE |
$119.46
|
|
MISCELLANEOUS PLUMBING FEES |
$256.00
|
|
MISCELLANOUS MECHANICAL FEES |
$146.00
|
|
Total Fees |
Charged: $4,300.21
Balance Due: $4,300.21
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 12/15/2017 | | |
More Info
|
RESIDENTIAL REVIEW | JIM COTTONE | APPROVED AS NOTED | | 1/1/1901 | |
More Info
|