11/15/2017 2:39:43 PM
PATIO COVER
* ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
*** NEED A FLATWORK INSPECTION BEFORE THE POUR. ***
**MAY NOT ADVERSELY AFFECT DRAINAGE OF NEIGHBORING PROPERTIES**
DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH ROOF OR LESS. MINIMUM 2/12 PITCH FOR COMPOSITION SHINGLES
* OUTSIDE OF POST CAN NOT ENCROACH THE REAR YARD SETBACK, UP TO THREE FOOT OVER-HANG IS ALLOWED.
*** FIREPLACE, FIRE PIT, OUTDOOR KITCHEN (BBQ GRILL, SINK, ETC) NOT REQUESTED OR PERMITTED. ***
***LAG BOLT MUST PENETRATE MAIN HOUSE STUD MIN 1 ½".
***MAY NOT INTRUDE ON SIDE YARD SETBACKS.
GRILL AREA
* ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
MAY NOT INTRUDE ON SIDE YARD SETBACKS. EXCEPTION: MAY ENCROACH UP TO 7 FT ON CORNER LOTS.
**A GAS LINE PRESSURE TEST IS REQUIRED WHEN ADDING GAS TO AN OUTDOOR
APPLIANCE**
MUST BE 3’ FROM SIDE PROPERTY LINE ONCE PAST REAR BUILD LINE. MUST BE 10’ FROM REAR PROPERTY LINE.
FIREPLACE
* ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS.
* VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
MUST MAINTAIN CLEARANCES PER R1001.11 2015 IRC.
* CHIMNEY MUST MAINTAIN A MINIMUM OF 2' CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
* FOOTER THICKNESS 12" MIN & WIDTH 6" EACH SIDE OF FIREPLACE WALL.
*100% MASONRY STRUCTURE, NO GREATER THAN 8 FT MAY ENCROACH INTO THE REAR YARD UP TO 10 FT FROM PROPERTY LINE.*
**MAY NOT INTRUDE ON SIDE YARD SETBACK. EXCEPTION: MAY ENCROACH UP TO 7 FT ON CORNER LOTS.**
** A GASLINE PRESSURE TEST IS REQUIRED WHEN ADDING GAS TO AN OUTDOOR FIREPLACE **
SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.