Permit Info
Short Description:
4566 AC, 6137 SF, SFR / 1 STORY
Expiration Date:
3/29/2018
Notes:
4566 AC, 6137 SF, SFR / 1 STORY
9/6/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS. EMERGENCY/ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF >= 5.7 SQFT. MINIMUM NET CLEAR HEIGHT OF 24" & NET CLEAR WIDTH OF 20" (GRADE FLOOR OR BELOW >= 5.0SQFT).
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
SINGLE STORY
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
NEWMAN VILLAGE PHASE 3
|
APPLICANT | DARLING HOMES OF TEXAS LLC | (972)624-4100 | chbrown@darlinghomes.com | | FRISCO, TX 75034 |
OWNER | DARLING HOMES OF TEXAS LLC | (972)624-4100 | chbrown@darlinghomes.com | | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES OF TEXAS LLC | (972)624-4100 | chbrown@darlinghomes.com | | FRISCO, TX 75034 |
ENGINEER | MLAW ENGINEERS | (512)835-7000 | jlhavelka@mlaw-eng.com | | AUSTIN, TX 78758 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NELROD CO | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
STRUCT ENG | MLAW ENGINEERS | (512)835-7000 | jlhavelka@mlaw-eng.com | | AUSTIN, TX 78758 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES LLC | (972)292-1478 | MATTGOLDBERG@IN-CHARGE-ELECTRIC.COM | | LEWISVILLE, TX T5057 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | JSINCLAIR@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
|
BUILDING PERMIT FEE |
$2,198.75
|
|
FENCE FEE |
$20.00
|
|
MISCELLANEOUS PLUMBING FEES |
$296.00
|
|
MISCELLANOUS MECHANICAL FEES |
$152.50
|
|
RESIDENTIAL ELECTRIC FEE |
$184.11
|
|
THOROUGHFARE IMPACT FEE |
$4,597.00
|
|
WATER IMPACT FEE |
$2,439.00
|
|
SEWER IMPACT FEE |
$1,982.00
|
|
Total Fees |
Charged: $11,869.36
Balance Due: $11,869.36
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 8/16/2017 | | |
More Info
|
RESIDENTIAL REVIEW | Curtis Winton | APPROVED AS NOTED | 8/16/2017 | 9/6/2017 | |
More Info
|