Permit Info
Short Description:
3553 AC, 4476 SF, SFR / 2 STORY
Expiration Date:
1/30/2018
Notes:
3553 AC, 4476 SF, SFR / 2 STORY
7/25/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
017. BEAMS=10"W X 36"D. INTERIOR
018. BEAMS=10"W X 42"D. EXTERIOR
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
SINGLE STORY
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
EDGESTONE AT LEGACY PH 1
|
| APPLICANT | HIGHLAND HOMES | (972)789-3500 | ryoung@hhomesltd.com | 12345 Burnt Prairie | Frisco, TX 75033 |
| OWNER | HIGHLAND HOMES | (972)789-3500 | ryoung@hhomesltd.com | 12345 Burnt Prairie | Frisco, TX 75033 |
| CONTRACTOR | HIGHLAND HOMES | (972)789-3500 | ryoung@hhomesltd.com | 12345 Burnt Prairie | Frisco, TX 75033 |
| ENGINEER | ERIC L DAVIS ENGINEERING INC | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
| HERS PROVIDE | FOX ENERGY SPECIALIST / THE NELROD CO | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
| STRUCT ENG | ERIC L DAVIS ENGINEERING INC | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
| ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES LLC | (972)292-1478 | MATTGOLDBERG@IN-CHARGE-ELECTRIC.COM | | LEWISVILLE, TX T5057 |
| MECH. CTR. | ADVENT AIR CONDITIONING INC | (972)221-4373 | aramon@adventair.com | | LEWISVILLE, TX 75057 |
| PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP INC | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
|
| BUILDING PERMIT FEE |
$1,823.75
|
8/3/2017
|
| FENCE FEE |
$20.00
|
8/3/2017
|
| MISCELLANEOUS PLUMBING FEES |
$261.00
|
8/3/2017
|
| MISCELLANOUS MECHANICAL FEES |
$146.00
|
8/3/2017
|
| RESIDENTIAL ELECTRIC FEE |
$134.28
|
8/3/2017
|
| SEWER IMPACT FEE |
$1,619.00
|
8/3/2017
|
| THOROUGHFARE IMPACT FEE |
$0.00
|
|
| WATER IMPACT FEE |
$1,845.00
|
8/3/2017
|
| Total Fees |
|
Charged: $5,849.03
Balance Due: $0.00
|
There are currently no inspections on this record.
|
| INITIAL REVIEW | DEMETRI JOHNSON | | 7/10/2017 | | |
More Info
|
| RESIDENTIAL REVIEW | Curtis Winton | APPROVED AS NOTED | 7/10/2017 | 7/25/2017 | |