Permit Info
Short Description:
3869 AC, 4761 SF, SFR / 2 STORY
Expiration Date:
1/3/2018
Notes:
3869 AC, 4761 SF, SFR / 2 STORY
7/3/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
014. BEAMS=10"W X 28"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
024. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
055. WRITTEN COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO IN THE PERMIT POUCH.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
** FINAL PLAT HAS FENCE NOTE **
*** 2ND STORY - GR, M, 2BR & 2BA ***
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PHILLIPS CREEK RANCH RIVERTON PHASE 7
|
APPLICANT | CALATLANTIC HOMES | (469)731-3111 | PermitDallas@stanpac.com | | IRVING, TX 75039 |
OWNER | CALATLANTIC HOMES | (469)731-3111 | PermitDallas@stanpac.com | | IRVING, TX 75039 |
CONTRACTOR | CALATLANTIC HOMES | (469)731-3111 | PermitDallas@stanpac.com | | IRVING, TX 75039 |
ENGINEER | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | jkillebrew@metrocode.com | | FT WORTH, TX 76116 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES LLC | (972)292-1478 | MATTGOLDBERG@IN-CHARGE-ELECTRIC.COM | | LEWISVILLE, TX T5057 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | JSINCLAIR@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8338 | aschmiat@lsmech.com | | RICHARDSON, TX 75081 |
|
BUILDING PERMIT FEE |
$1,938.75
|
|
FENCE FEE |
$20.00
|
|
MISCELLANEOUS PLUMBING FEES |
$270.00
|
|
MISCELLANOUS MECHANICAL FEES |
$146.00
|
|
RESIDENTIAL ELECTRIC FEE |
$142.83
|
|
THOROUGHFARE IMPACT FEE |
$3,816.00
|
|
WATER IMPACT FEE |
$1,772.00
|
|
SEWER IMPACT FEE |
$0.00
|
|
Total Fees |
Charged: $8,105.58
Balance Due: $8,105.58
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 6/19/2017 | | |
More Info
|
RESIDENTIAL REVIEW | Carey L Frazier | APPROVED AS NOTED | 6/30/2017 | 7/3/2017 | |
More Info
|