Permit Info
Short Description:
3477 AC, 4745 SF COV'D , SFR / 2 STORY
Notes:
3477 AC, 4745 SF COV'D , SFR / 2 STORY
6/26/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 4 RISERS OR MORE REQUIRE A HANDRAIL
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
054. LETTERS OF ACCEPTANCE FOR FOUNDATION & FRAME REQUIRED FROM BOTH ENGINEERS FOR CO.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(6/26/2017 3:24 PM JC)
(FWF)
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
HOLLYHOCK PHASES 1B & 1C
|
APPLICANT | BRITTON HOMES / PERRY HOMES CO | (972)629-3892 | victoria.haase@brittonhomestexas.com | 9000 Gulf Freeway | Houston, TX 77017 |
OWNER | BRITTON HOMES / PERRY HOMES CO | (972)629-3892 | victoria.haase@brittonhomestexas.com | 9000 Gulf Freeway | Houston, TX 77017 |
CONTRACTOR | BRITTON HOMES / PERRY HOMES CO | (972)629-3892 | victoria.haase@brittonhomestexas.com | 9000 Gulf Freeway | Houston, TX 77017 |
ENGINEER | STRAND SYSTEMS ENGINEERING | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NELROD CO | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
ELECT. CTR. | L & S MECHANICAL (elec) | (214)393-8327 | rtoole@lsmech.com | | RICHARDSON, TX 75081 |
MECH. CTR. | L & S MECHANICAL (mech) | (214)393-8322 | lyork@lsmech.com | | RICHARDSON, TX 75081 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8338 | aschmiat@lsmech.com | | RICHARDSON, TX 75081 |
|
WATER IMPACT FEE |
$635.00
|
|
SEWER IMPACT FEE |
$1,619.00
|
|
BUILDING PERMIT FEE |
$1,893.75
|
|
FENCE FEE |
$20.00
|
|
MISCELLANEOUS PLUMBING FEES |
$263.00
|
|
MISCELLANOUS MECHANICAL FEES |
$152.50
|
|
RESIDENTIAL ELECTRIC FEE |
$142.35
|
|
Total Fees |
Charged: $4,725.60
Balance Due: $4,725.60
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 6/6/2017 | | |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | APPROVED AS NOTED | 6/26/2017 | 6/26/2017 | |
More Info
|