Notes:
625 SQ FT, CADD / SHADE STRUCTURES
6/28/2017 12:00:00 AM
1-Awnings and canopies shall be designed and constructed to withstand wind or other lateral loads and live loads as required by chapter 16. Structural members shall be protected to prevent deterioration.
Awnings shall have frames of noncombustible material, fire-retardant-treated wood, wood of Type IV size, or 1-hour construction with combustible or noncombustible covers and shall be either fixed, retractable, folding or collapsible.
2-Awnings and canopies shall be provided with an approved covering that meets the fire propagation performance criteria of Tet Method 1 or Test Method 2, as appropriate, of NFPA 701 or has a flame spread index not greater than 25 when tested in accordance with ASTM E84 or UL 723.
3- All work performed must meet the 2015 IBC standards and abide by the city of Frisco’s Zoning ordinance (06-18-13).
4- Subject to field inspection and approval.
5-Call (972) 292-5386 for inspections.