Permit Info
Short Description:
3349 AC, 3961 SF, SFR / 2 STORY
Expiration Date:
12/2/2017
Notes:
3349 AC, 3961 SF, SFR / 2 STORY
5/19/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
013. BEAMS=10"W X 26"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
024. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
025. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
026. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS. EMERGENCY/ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF >= 5.7 SQFT. MINIMUM NET CLEAR HEIGHT OF 24" & NET CLEAR WIDTH OF 20" (GRADE FLOOR OR BELOW >= 5.0SQFT).
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 2BR, 1BA, GAME.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
LEXINGTON PHASE FOUR (CFR)
|
APPLICANT | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
OWNER | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
CONTRACTOR | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
ENGINEER | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
MECH. CTR. | AIRTRON INC. | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8322 | rtoole@lsmech.com | | RICHARDSON, TX 75081 |
|
BUILDING PERMIT FEE |
$1,743.75
|
|
FENCE FEE |
$20.00
|
|
MISCELLANEOUS PLUMBING FEES |
$235.00
|
|
MISCELLANOUS MECHANICAL FEES |
$139.50
|
|
RESIDENTIAL ELECTRIC FEE |
$119.31
|
|
WATER IMPACT FEE |
$1,772.00
|
|
SEWER IMPACT FEE |
$1,619.00
|
|
Total Fees |
Charged: $5,648.56
Balance Due: $5,648.56
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 4/28/2017 | | |
More Info
|
RESIDENTIAL REVIEW | Curtis Winton | APPROVED AS NOTED | 4/28/2017 | 6/2/2017 | |
More Info
|
MISC REVIEW | Curtis Winton | N/A | 5/19/2017 | 5/19/2017 | |
More Info
|