SALT, REROOF / CYPRESS CREEK MONTESSORI
3/28/2017 12:00:00 AM
100% of all roof areas shall comply with the specifications of the federal environmental protection agency’s energy star cool roof program, as it exists or may be amended. Ultra-Ply TPO Membrane. 3.5” ISO (R-20.5ci).
All work performed must meet the 2015 IBC standards, local amendments and abide by the city of Frisco comprehensive zoning ordinance and all other city ordinances.
Subject to field inspections.
Call (972) 292-5386 for inspection.
* Project is subject to the "Cool roof" program (Energy Star) with minimum; (IECC 402.2.1.1) Low Slope Roofs {2:12} Initial Solar Reflectance value of 0.70 & 0.55 (after 3 years); Initial Thermal Emittance of 0.75 or more & 0.75 (after 3 years). Initial Solar Reflectance Index {SRI} of 82 and 64 (after 3 years ). For steep roofs Solar reflectance of 0.25 (initial), 0.15 (after 3 years); 0.80 or more Thermal Emittance. Manufacturer’s documentation of selected roofing materials must be submitted in details. (info must include the "after-3-years" values as required). Skylights to be code compliant with (sec.2405 IBC) & fully detailed as per required construction. http://www.energystar.gov/index.cfm?fuseaction=find_a_product.showProductGroup&pgw_code=RO
Subject to field inspections.
Call (972) 292-5386 for inspection.