Permit Info
Short Description:
CANCELLED 2526 AC, 3265 SF, SFR / 1 STORY
Notes:
CANCELLED 2526 AC, 3265 SF, SFR / 1 STORY
6/24/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
011. BEAMS=8"W X 30"D.
025. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
054. LETTERS OF ACCEPTANCE FOR FOUNDATION & FRAME REQUIRED FROM BOTH ENGINEERS FOR CO.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
THE HILLS OF KINGSWOOD PHASE 2B
|
APPLICANT | ASHTON WOODS HOMES | (972)428-5404 | lola.moore@ashtonwoods.com | | FARMERS BRANCH, TX 75234 |
OWNER | ASHTON WOODS HOMES | (972)428-5404 | lola.moore@ashtonwoods.com | | FARMERS BRANCH, TX 75234 |
CONTRACTOR | ASHTON WOODS HOMES | (972)428-5404 | lola.moore@ashtonwoods.com | | FARMERS BRANCH, TX 75234 |
HERS PROVIDE | TEXENERGY SOLUTIONS | (972)579-2009 | STEPHEN.FUKUCHI@TEXENERGY.ORG | | IRVING, TX 75061 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | KEN-MAN PLUMBING | (817)453-8032 | kbennett@ken-mancorp.com | | MANSFIELD, TX 76063 |
|
THOROUGHFARE IMPACT FEE |
$0.00
|
|
WATER IMPACT FEE |
$0.00
|
|
SEWER IMPACT FEE |
$1,619.00
|
|
BUILDING PERMIT FEE |
$1,438.75
|
|
FENCE FEE |
$20.00
|
|
MISCELLANEOUS ELECTRICAL FEES |
$98.00
|
|
MISCELLANEOUS PLUMBING FEES |
$235.00
|
|
MISCELLANOUS MECHANICAL FEES |
$139.00
|
|
Total Fees |
Charged: $3,549.75
Balance Due: $3,549.75
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 6/20/2016 | | 7/9/2016 |
More Info
|
RESIDENTIAL REVIEW | EDWIN ALFARO | APPROVED AS NOTED | 6/20/2016 | 6/24/2016 | |
More Info
|