Notes:
581 SQ FT, SALT / GAZEBO
12/8/2016 12:00:00 AM
NEED PDF OF PLANS AND ENERGY FORMS OR CD
105. *** NEED A FLATWORK INSPECTION BEFORE THE POUR. ***
**MAY NOT ADVERSELY AFFECT DRAINAGE OF NEIGHBORING PROPERTIES**
142. * ALL WORK PERFORMED MUST MEET THE 2012 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
145. * OUTSIDE OF BRICK CAN NOT ENCROACH THE 10' REAR AND 10' SIDE YARD SETBACKS, UP TO THREE FOOT OVER-HANG IS ALLOWED.
143. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
EXTERIOR FACADES FOR ENCLOSED STRUCTURES:
THE EXTERIOR FACSDES OF ALL ACCESSORY STRUCTURES, INCLUDING DETACHED GARAGES, IN ALL ZONING DISTRICTS, SHALL BE CONSTRUCTED OF THE SAME EXTERIOR CONSTRUCTION MATERIAL OF THE MAIN BUILDING OR
STRUCTURE.
FIREPLACE
172. * ALL WORK PERFORMED MUST MEET THE 2012 IRC STANDARDS.
175. * FIREPLACE MUST BE 100% MASONRY.
176. * VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
177. * MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTABLE ITEMS.
178. * CHIMNEY MUST MAINTAIN A MINIMUM OF 2' CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF ROOF.
ELECTRICAL
* ALL WORK PERFORMED MUST MEET THE 2011 NEC AND 2012 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDIANCES.
01. MINIMUM #12 COPPER CONDUCTORS PERMITTED EXCEPT FOR CONTROLS.
02. NO ALUMINIM WIRE PERMITTED OR #14
IEC3 ENERGY REQUIREMENT REQUIRED FOR ADDITIONS
054. ENGINEERS LETTERS OF ACCEPTANCE FOR FRAMING AND FLOORING SYSTEM REQUIRED PRIOR TO THE CITY OF FRISCO FRAME INSPECTION.
193. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.