Notes:
1811 SQ FT, SADD / ADD 3 CAR GARAGE, 3 BEDROOMS & 1 BATHROOM
1/12/2016 12:00:00 AM
ADD 3 CAR GARAGE, 3 BEDROOMS & 1 BATHROOM & WORKSHOP SEE DETAILS
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET
019. BEAMS=12"W X 24"D.
020. PIERS 12''X15' OR PENATRATE BEDROCK.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE
032. TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
054. LETTERS OF ACCEPTANCE FOR FOUNDATION & FRAME REQUIRED FROM ENGINEER FOR CO.
052. ENGINEERS INSPECTION REPORT REQUIRED FOR PIER HOLE INSPECTION AND PRE POUR SLAB.
150. ALL FACADES (EXTERIOR) MATERIALS MUST REFLECT EARLY 20TH CENTURY TEXAS ARCHITECTURAL STYLES SAME AS THE EXISTING STRUCTURE.
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.
165. MAY NOT INTRUDE ON SIDE OR REAR YARD SETBACKS.
166. 100% BRICK AT FIRST FLOOR LEVEL.
EXISTING GARAGE/WORK SHOP MUST BE REMOVED PRIOR TO BUILDING FINAL OF MAIN HOUSE.