Permit Info
Short Description:
3263 AC, 4308 SF, SFR / 2 STORY
Approved Date:
12/18/2015
Notes:
3263 AC, 4308 SF, SFR / 2 STORY
12/18/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
011. BEAMS=8"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
THE HILLS OF KINGSWOOD PHASE 2A
|
APPLICANT | ASHTON WOODS HOMES | (972)428-5404 | ANITA.TATUM@ASHTONWOODS.COM | | FARMERS BRANCH, TX 75234 |
OWNER | ASHTON WOODS HOMES | (972)428-5404 | ANITA.TATUM@ASHTONWOODS.COM | | FARMERS BRANCH, TX 75234 |
CONTRACTOR | ASHTON WOODS HOMES | (972)428-5404 | ANITA.TATUM@ASHTONWOODS.COM | | FARMERS BRANCH, TX 75234 |
HERS PROVIDE | TEXENERGY SOLUTIONS | (972)579-2009 | STEPHEN.FUKUCHI@TEXENERGY.ORG | | IRVING, TX 75061 |
STRUCT ENG | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | KEN-MAN PLUMBING | (817)453-8032 | JLANE@KEN-MANCORP.COM | | MANSFIELD, TX 76063 |
|
BUILDING PERMIT FEE |
$1,713.75
|
|
FENCE FEE |
$20.00
|
|
MISCELLANEOUS PLUMBING FEES |
$249.00
|
|
MISCELLANOUS MECHANICAL FEES |
$146.00
|
|
RESIDENTIAL ELECTRIC FEE |
$129.24
|
|
THOROUGHFARE IMPACT FEE |
$0.00
|
|
WATER IMPACT FEE |
$0.00
|
|
SEWER IMPACT FEE |
$0.00
|
|
Total Fees |
Charged: $2,257.99
Balance Due: $2,257.99
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Laurie Weddle | | 12/8/2015 | | |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | APPROVED AS NOTED | 12/8/2015 | 12/21/2015 | |
More Info
|