Notes:
648 SQ FT, SALT / ARBOR, FIREPLACE & CONCRETE
3/12/2015 12:00:00 AM
105. *** NEED A FLATWORK INSPECTION BEFORE THE POUR. ***
108. * CONCRETE PATIO MUST BE AT LEAST THREE FEET FROM REAR PROPERTY LINE AND THREE FEET FROM SIDE PROPERTY LINES, (CAN BE ONE FOOT FROM REAR PROPERTY & ONE FOOT FROM SIDE PROPERTY IF NOT BACKING UP TO A LOT.)
103. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
**MAY NOT ADVERSELY AFFECT DRAINAGE OF NEIGHBORING PROPERTIES**
142. * ALL WORK PERFORMED MUST MEET THE 2012 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
145. * OUTSIDE OF POST CAN NOT ENCROACH THE 10' REAR YARD SETBACK ALLOWED FOR OPEN AIR ARBOR, UP TO THREE FOOT OVER-HANG IS ALLOWED.
146. *** NO ELECTRICAL OR PLUMBING PERMIT REQUESTED OR ISSUED ***
147. *** FIRE PIT, OUTDOOR KITCHEN (BBQ GRILL, SINK, ETC) NOT REQUESTED OR PERMITTED. ***
148. ***LAG BOLT MUST PENETRATE MAIN HOUSE STUD MIN 1 ½".
151. ***MAY NOT INTRUDE ON SIDE YARD SETBACKS.
175. * FIREPLACE MUST BE 100% MASONRY.
176. * VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
177. * MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTABLE ITEMS.
178. * CHIMNEY MUST MAINTAIN A MINIMUM OF 2' IN CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
179. * FOOTER THICKNESS 12" MIN & WIDTH 6" EACH SIDE OF FIREPLACE WALL.
*100% MASONRY STRUCTURE, NO GREATER THAN 8 FT MAY ENCROACH INTO THE REAR YARD UP TO 10 FT FROM PROPERTY LINE.*
** A GASLINE PRESSURE TEST IS REQUIRED WHEN ADDING GAS TO AN OUTDOOR FIREPLACE **
173. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.