Short Description:
4337 AC, 5198 SF, SFR / 2 STORY
Notes:
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
014. BEAMS=10"W X 30"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
025. WINDOW BOX-OUTS WITH SIDING & TRIM MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
047. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(MFD)
4337 AC, 5198 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PHILLIPS CREEK RANCH, PH 4B
|
APPLICANT | K HOVNANIAN HOMES | (469)534-4709 | cfarrell@khov.com | | PLANO, TX 75093 |
OWNER | K HOVNANIAN HOMES | (469)534-4709 | cfarrell@khov.com | | PLANO, TX 75093 |
CONTRACTOR | K HOVNANIAN HOMES | (469)534-4709 | cfarrell@khov.com | | PLANO, TX 75093 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | | DALLAS, TX 75201 |
ELECT. CTR. | SWARTZ ELECTRIC | (972)254-3480 | info@swartz-electric-inc.com | | IRVING, TX 75061 |
MECH. CTR. | BELL MECHANICAL SERVICES | (225)752-8538 | mike@bellmechanical.com | | BATON ROUGE, LA 70879 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
|
THOROUGHFARE IMPACT FEE |
$3,816.00
|
|
WATER IMPACT FEE |
$1,772.00
|
|
SEWER IMPACT FEE |
$0.00
|
|
RESIDENTIAL ELECTRIC FEE |
$155.94
|
|
MISCELLANOUS MECHANICAL FEES |
$165.50
|
|
MISCELLANEOUS PLUMBING FEES |
$291.00
|
|
BUILDING PERMIT FEE |
$2,113.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $8,334.19
Balance Due: $8,334.19
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 1/28/2015 | | |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | APPROVED AS NOTED | 1/28/2015 | 2/11/2015 | |
More Info
|