Permit Info
Short Description:
3214 AC, 3890 SF, SFR / 2 STORY
Expiration Date:
8/8/2013
Notes:
3214 AC, 3890 SF, SFR / 2 STORY
8/7/2013 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188).
2nd FLOOR: 2-BED ROOMS, 1-BATH, GAME & MEDIA ROOMS.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PCR - SHERIDAN
|
APPLICANT | BBL INTEREST LLC DBA LIONSGATE | (972)428-3032 | Jwilds@lionsgatetx.com | | CARROLLTON, TX 75006 |
OWNER | BBL INTEREST LLC DBA LIONSGATE | (972)428-3032 | Jwilds@lionsgatetx.com | | CARROLLTON, TX 75006 |
CONTRACTOR | BBL INTEREST LLC DBA LIONSGATE | (972)428-3032 | Jwilds@lionsgatetx.com | | CARROLLTON, TX 75006 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)441-9795 | JMCDONALD@ENERGYINSPECTOR.COM | | MCKINNEY, TX 75071 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75082 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
|
THOROUGHFARE IMPACT FEE |
$0.00
|
|
WATER IMPACT FEE |
$0.00
|
|
SEWER IMPACT FEE |
$0.00
|
|
RESIDENTIAL ELECTRIC FEE |
$116.70
|
|
MISCELLANOUS MECHANICAL FEES |
$129.50
|
|
MISCELLANEOUS PLUMBING FEES |
$218.00
|
|
BUILDING PERMIT FEE |
$1,693.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $2,177.95
Balance Due: $2,177.95
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | | 7/31/2013 | | 8/21/2013 |
More Info
|
RESIDENTIAL REVIEW | Victor Insko | APPROVED AS NOTED | 7/31/2013 | 8/7/2013 | 8/21/2013 |
More Info
|