Notes:
8571 SQ FT, SALT / COMPLETE B07-2079
3/8/2013 12:00:00 AM
PERMIT TO REPAIR AND COMPLETE CONSTRUCTION OF STRUCTURE ORIGINALLY PERMITTED B07-2079.
STRUCTURAL AND MASONRY REPAIRS PER ENGINEERED DESIGN.
SEE REVEIW NOTES FROM ORINGINAL PERMIT.
NEED MEP CONRACTORS VERIFICATION.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
09. BEAMS=10"W X 26"D.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
42. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. COMPLIANCE WITH THE US DEPT OF ENERGY (01/23/06 REQUIRMENTS) AND 2003 IECC REQUIRED.
(8/21/2007 08:44 JC)
This permit does not include the Pergola, pool or fountain. It is suggested that the wine cellar include a mech. closet with a sump and pump with discharge to day light.
(1/18/2008 14:05 JM)
1. ROOF HEIGHT CHANGED TO 33' FROM GRADE TO HIGHEST RIDGE BEAM, INSTEAD OF 42'.
2. OMIT D0G KENNEL.
3. ALL WORK SUBJECT TO FIELD APPROVED INSPECTIONS AND TESTING.
4. REVISED PLANS TO REMAIN ON SITE THROUGHOUT CONSTRUCTION