Permit Info
Short Description:
*VOID*3196 AC, 3741 SF, SFR / 2 STORY
Approved Date:
10/15/2010
Notes:
*VOID*3196 AC, 3741 SF, SFR / 2 STORY
10/15/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
WINDING CREEK ESTATES (CFR)
|
APPLICANT | ASHTON WOODS HOMES | (972)301-6600 | | 1511 LBJ FREEWAY SUITE 1500 | DALLAS, TX 75251 |
OWNER | ASHTON WOODS HOMES | (972)301-6600 | | 1511 LBJ FREEWAY SUITE 1500 | DALLAS, TX 75251 |
CONTRACTOR | ASHTON WOODS HOMES | (972)301-6600 | | 1511 LBJ FREEWAY SUITE 1500 | DALLAS, TX 75251 |
HERS PROVIDE | TEXENERGY SOLUTIONS | (972)579-2009 | SELLISON@TEXENERGY.ORG | 2611 E. PIONEER | IRVING, TX 75061 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | SWARTZ ELECTRIC | (972)254-3480 | SCHASE@SWARTZ-ELECTRIC-INC.COM | 228 IRBY LANE | IRVING, TX 75061 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | DAVID.GANNON@TEMPOAIR.COM | 2611 E PIONEER DR | IRVING, TX 75061 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | BHALLIBURTON@HORIZONPLUMBING.NET | 3610 WEST PIONEER PARKWAY #207 | ARLINGTON, TX 76013 |
|
RESIDENTIAL ELECTRIC FEE |
$112.23
|
|
MISCELLANOUS MECHANICAL FEES |
$123.00
|
|
MISCELLANEOUS PLUMBING FEES |
$204.00
|
|
BUILDING PERMIT FEE |
$1,688.75
|
|
FENCE FEE |
$20.00
|
|
THOROUGHFARE IMPACT FEE |
$4,000.00
|
|
WATER IMPACT FEE |
$1,911.00
|
|
SEWER IMPACT FEE |
$1,553.00
|
|
Total Fees |
Charged: $9,611.98
Balance Due: $9,611.98
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | | 10/8/2010 | | 10/29/2010 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | Approved as Noted | 10/8/2010 | 10/8/2010 | 10/29/2010 |
More Info
|