Permit Info
Short Description:
SEE B17-02024, 5456 AC, 6448 SF, SFR / 2 STORY
Notes:
*EXPIRED*5456 AC, 6448 SF, SFR / 2 STORY
8/31/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
020. W/12" DIA. PIERS W/(1) #5 REBAR.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
040. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
053. SEE THE ENCLOSED ONE (1) HOUR FIREWALL DESIGN SKETCH.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
STARWOOD #4 VILLAGE #18 (CFR)
|
APPLICANT | PECKHAM CUSTOM BLDG LTD | (972)931-0200 | MIKE@PECKHAMCUSTOMBUILDERS.COM | 17480 DALLAS PKWY #219 | DALLAS, TX 75287 |
OWNER | PECKHAM CUSTOM BLDG LTD | (972)931-0200 | MIKE@PECKHAMCUSTOMBUILDERS.COM | 17480 DALLAS PKWY #219 | DALLAS, TX 75287 |
CONTRACTOR | PECKHAM CUSTOM BLDG LTD | (972)931-0200 | MIKE@PECKHAMCUSTOMBUILDERS.COM | 17480 DALLAS PKWY #219 | DALLAS, TX 75287 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | DJ'S PLUMBING & BACKFLOW INC | (214)543-6026 | | 4208 WILD PLUM | Carrollton, TX 75010 |
|
RESIDENTIAL ELECTRIC FEE |
$193.44
|
|
MISCELLANOUS MECHANICAL FEES |
$162.50
|
|
MISCELLANEOUS PLUMBING FEES |
$260.00
|
|
BUILDING PERMIT FEE |
$2,468.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $3,104.69
Balance Due: $3,104.69
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | | 8/23/2010 | | 9/13/2010 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | Approved as Noted | 8/23/2010 | 8/23/2010 | 9/13/2010 |
More Info
|